Team:Newcastle/13 August 2010

From 2010.igem.org

Revision as of 13:20, 18 August 2010 by Alankoh (Talk | contribs)

iGEM Homepage Newcastle University BacillaFilla Homepage Image Map

Contents

rocF BioBrick miniprep

Aims

The aim of this experiment is to extract pSB1C3 containing the rocF BioBrick from E. coli DH5α cells with the help of Qiagen miniprep kit and confirming the extraction with the help of a nanodrop experiment.

Materials and Protocol

Please refer to: Minipreps for Qiagen miniprep protocol, Nanodrop Spectrophotometer for nanodrop protocol.

Result

pSB1C3 with rocF BioBrick (no. 1) pSB1C3 with rocF BioBrick (no. 2) pSB1C3 with rocF BioBrick (no. 3) pSB1C3 with rocF BioBrick (no. 4) pSB1C3 with rocF BioBrick (no. 5) pSB1C3 with rocF BioBrick (no. 6)
90.3 µl/ml 64.4 µl/ml 286.9 µl/ml 87.1 µl/ml 780.5 µl/ml 59.1 µl/ml

Table 1: Nanodrop spectrophotometer experiment result. Table represents the amount of plasmid present in µl/ml quantity.

Discussion

The tube containing plasmid pSB1C3 with rocF BioBrick (no.3) has the highest concentration with a high purity value.

Conclusion

Overall the plasmid miniprep was successful and we would be using Tube no. 3 containing plasmid pSB1C3 with rocF BioBrick.

rocF BioBrick gel electrophoresis

Aims

The aim of this experiment is to run gel electrophoresis for the extracted plasmid pSB1C3 containing rocF BioBrick.

Materials and Protocol

Please refer to: Gel electrophoresis for gel electrophoresis protocol.

Result

Newcastle 130810 gel.png

Figure 1: Gel electrophoresis of the miniprep products required for the confirmation of Gibson procedure.

  • Lane 1: 1 kb DNA ladder
  • Lane 2: pSB1C3 with rocF BioBrick (no. 1)
  • Lane 3: pSB1C3 with rocF BioBrick (no. 2)
  • Lane 4: pSB1C3 with rocF BioBrick (no. 3)
  • Lane 5: pSB1C3 with rocF BioBrick (no. 4)
  • Lane 6: pSB1C3 with rocF BioBrick (no. 5)
  • Lane 7: pSB1C3 with rocF BioBrick (no. 6)
  • Lane 8: 1 kb DNA ladder

Discussion

The expect band size is supposed to be 3195 bp after Gibson procedure ligation. In the Figure 1, we can see that in Lane 2 and 5 we got a band of approximately 3200 bp but we found that it is because of the initial insert (rfp gene) which was present in the plasmid pSB1C3 i.e. these 2 sequences are of the template DNA which were used during PCR reaction few days ago. The other 4 bands are of approximately 2100 bp in size.

Result

Overall the GIbson protocol has failed. We did not receive bands of correct size thus showing that the rfp fragments and the plasmid pSB1C3 did not ligate at all. The 2 bands of approximately 3200 bp size are of the plasmid pSB1C3 containing rfp gene insert and thus these fragments are of template DNA for the PCR reaction which had taken place few days ago. The explanation for the failure of the Gibson protocol is as following:

  1. Because of the presence of the BioBrick prefix and suffix sequences at the ends of the fragments, the fragments circularized and ligated with themselves. This is because both prefix and suffix contains Not1 restriction site and Xba1 and Spe1 restriction site which have similar sequences and thus during ligation step of the Gibson reaction, the fragments containing prefix and suffix religate with themselves

Subtilin Immunity BioBrick

Aims

We plan to select three spaIFEG gene (part 3) PCR tubes, using Tms 51°C, 56°C and 61°C (we had confirmed it successful from yesterday's gel electrophoresis - please refer to the gel electrophoresis from yesterday). Gel extraction will then be performed, along with Plasmid Vector (part 1), Promoter & RBS (part 2) and Double terminator (part 4). Finally, NanoDrop will be performed on each of these four parts.

Materials and protocol

Please refer to the gel electrophoresis, gel extraction and NanoDrop protocols. Instead of using the centrifuge to bind the DNA from our sample to the QIAquick column, a vacuum manifold was used instead. It is the first time it had been used. The advantage of this was that the extraction could be carried out much faster as we had 7 samples. (photos)

Gel Extraction of spaIFEG genes

Setting up the tubes for the Vacuum Manifold Setting up the tubes for the Vacuum Manifold Vacuum Manifold with the tubes full Vacuum Manifold with the tubes empty

Results

The results from the Nanodrop Spectrophotometer of the four parts are as follows:

  • Vector - 21.3 ng/μl
  • Promoter - 28.8 ng/μl
  • Coding sequence - 27.0 ng/μl
  • Terminator - 27.5 ng/μl

Discussion

We chose the three spaIFEG gene (part 3) PCR tubes, using Tms 51°C, 56°C and 61°C because they were the mid-ranged Tms. Gel extraction was then performed, by firstly cutting the gels under U.V light, and then apply the protocol for completion.

Conclusion

The results from the NanoDrop reading suggests that our results were positive, which indicates that we have successfully extracted all the parts required for the Subtilin Immunity BioBrick. Gibson cloning method will be used next week.



Go back to our main Lab book page


Newcastle University logo.png    Newcastle cbcb logo.pngNewcastle Biomedicine logo.gif    Team Newcastle CEG logo.gif
Newcastle iww logo.jpg  UNIPV Pavia Logo.gif  Newcastle BBSRC.gif    Newcastle Genevision logo.png Newcastle WelcomeTrust.jpg
FaceBook Icon