Team:Newcastle/Gel extraction
From 2010.igem.org
(Difference between revisions)
Line 3: | Line 3: | ||
=QIAquick Gel Extraction Microcentrifuge Protocol= | =QIAquick Gel Extraction Microcentrifuge Protocol= | ||
- | # Excise the DNA fragment from the agarose gel with a clean, sharp scalpel. | + | ==Materials== |
+ | # Scalpel | ||
+ | # Eppendorf tubes | ||
+ | # Pipettes | ||
+ | # QIAquick column | ||
+ | # UV transluminator | ||
+ | # Buffer QG | ||
+ | # BufferPE | ||
+ | # Buffer EB | ||
+ | # Isopropanol | ||
+ | # 70% ethanol | ||
+ | |||
+ | ==Proceduce== | ||
+ | # Before extraction, clean the UV transilluminator and scalpel with 70% ethanol. | ||
+ | # Excise the DNA fragment from the agarose gel with a clean, sharp scalpel. ( Minimise the exposure of the gel to UV as much as possible.) | ||
+ | # Weight the gel slice and add 3 volumes of buffer QG to 1 volume of gel (100 mg ~ 100 µl). | ||
+ | # Incubate at 50°C and invert the tube gently at regular interval until the gel has completely dissolved. | ||
+ | # After the gel has dissolved completely, check that the color of the mixture is yellow. | ||
+ | # Add 1 gel volume of isopropanol to the sample and mix. | ||
+ | # Place a QIAquick spin column in a 2 ml collection tube | ||
+ | # To bind DNA, apply the sample to the QIAquick column and centrifuge for 1 min. | ||
+ | # Discard the flow through and place the QIAquick column back into the same tube (max volume: 750 µl). | ||
+ | # Add 0.5 ml of Buffer QG to QIAquick column and centrifuge for 1 min. Discard the flow through and place the QIAquick column back into the same tube. | ||
+ | # To wash, add 0.75 ml of Buffer PE to QIAquick column and centrifuge for 1 min. Place the QIAquick column back into the same tube. | ||
+ | # Centrifuge the column for a further 1 min. | ||
+ | # Transfer the column into a clean 1.5 ml microcentrifuge tube. | ||
+ | # To elute DNA, add 30 µl of Buffer EB to the center of the QIAquick membrane and allow to stand for 1 min. | ||
+ | # Centrifuge the column for 1 min and transfer the eluate to a clean 1.5 ml micriocentrifuge tube. | ||
+ | # To measure the purity of the sample, use a [[TeamNewcastleNanoDrop Spectrophotometer| Nanodrop Spectrophotometer]]. | ||
{| | {| | ||
Line 19: | Line 47: | ||
|- | |- | ||
|} | |} | ||
- | |||
- | |||
- | |||
- | |||
- | |||
- | |||
- | |||
- | |||
- | |||
- | |||
- | |||
- | |||
- | |||
- | |||
- | |||
- | |||
- | |||
{{Team:Newcastle/footer}} | {{Team:Newcastle/footer}} |
Revision as of 11:21, 10 August 2010
|
QIAquick Gel Extraction Microcentrifuge Protocol
Materials
- Scalpel
- Eppendorf tubes
- Pipettes
- QIAquick column
- UV transluminator
- Buffer QG
- BufferPE
- Buffer EB
- Isopropanol
- 70% ethanol
Proceduce
- Before extraction, clean the UV transilluminator and scalpel with 70% ethanol.
- Excise the DNA fragment from the agarose gel with a clean, sharp scalpel. ( Minimise the exposure of the gel to UV as much as possible.)
- Weight the gel slice and add 3 volumes of buffer QG to 1 volume of gel (100 mg ~ 100 µl).
- Incubate at 50°C and invert the tube gently at regular interval until the gel has completely dissolved.
- After the gel has dissolved completely, check that the color of the mixture is yellow.
- Add 1 gel volume of isopropanol to the sample and mix.
- Place a QIAquick spin column in a 2 ml collection tube
- To bind DNA, apply the sample to the QIAquick column and centrifuge for 1 min.
- Discard the flow through and place the QIAquick column back into the same tube (max volume: 750 µl).
- Add 0.5 ml of Buffer QG to QIAquick column and centrifuge for 1 min. Discard the flow through and place the QIAquick column back into the same tube.
- To wash, add 0.75 ml of Buffer PE to QIAquick column and centrifuge for 1 min. Place the QIAquick column back into the same tube.
- Centrifuge the column for a further 1 min.
- Transfer the column into a clean 1.5 ml microcentrifuge tube.
- To elute DNA, add 30 µl of Buffer EB to the center of the QIAquick membrane and allow to stand for 1 min.
- Centrifuge the column for 1 min and transfer the eluate to a clean 1.5 ml micriocentrifuge tube.
- To measure the purity of the sample, use a Nanodrop Spectrophotometer.