In order assess and quantify the results a standard dilution of beta-carotene and retinal was made and measured: 10 µM, 5 µM, 1 µM, 2 µM, 0,5 µM. The standard dilutions was also measured on the HPLC with the same injection volumen and program as the samples. The resulting graphs is presented beneath the text<br>
In order assess and quantify the results a standard dilution of beta-carotene and retinal was made and measured: 10 µM, 5 µM, 1 µM, 2 µM, 0,5 µM. The standard dilutions was also measured on the HPLC with the same injection volumen and program as the samples. The resulting graphs is presented beneath the text<br>
-
[[Image:Team SDU-Denmark-HPLC standards1.png|300px|]]
+
[[Image:Team SDU-Denmark-HPLC standards1.png|300px|]]<br>
When looking at the retinal and beta-carotene standards analysed on the HPLC we clearly see peaks for both chemical. The retinal retention time is 3,480-3,490 minutes and the beta-carotene retention time is 23,300-23,600 minutes.<br>     
When looking at the retinal and beta-carotene standards analysed on the HPLC we clearly see peaks for both chemical. The retinal retention time is 3,480-3,490 minutes and the beta-carotene retention time is 23,300-23,600 minutes.<br>     