Team:Newcastle/3 August 2010

From 2010.igem.org

(Difference between revisions)
(Discussion)
(Discussion)
Line 46: Line 46:
==Discussion==
==Discussion==
-
Bands around 3000 bp were observed in lanes 2, 3 and 4, thereby indicating the correct products. Lane 5 contain the LacI plasmid,therefore it should be bigger in size as compared to the double terminator plasmid which is in lane 6. Therefore lane 5 might not contain the LacI plasmid. From the nanodrop results, the ratio of 260.280 nm ranged from 1.7 to 1.85 and the concentration ranged from 92.1 µl/ml to 246.7 µl/ml. These results indicated that the DNA extracted have low RNA cpntamination and the samples are pure.
+
Bands around 3000 bp were observed in lanes 2, 3 and 4, thereby indicating the correct products. Lane 5 contain the LacI plasmid,therefore it should be bigger in size as compared to the double terminator plasmid which is in lane 6. Therefore lane 5 might not contain the LacI plasmid. From the nanodrop results, the ratio of 260.280 nm ranged from 1.7 to 1.85 and the concentration ranged from 92.1 µl/ml to 246.7 µl/ml. These results indicated that the DNA extracted have low RNA contamination and the samples are pure.
==Conclusion==
==Conclusion==

Revision as of 21:40, 25 October 2010

iGEM Homepage Newcastle University BacillaFilla Homepage Image Map

Contents

Plasmid Miniprep Experiment

Aim

The aim of this experiment is to extract plasmid DNA pSB1C3 and pSB1AK3 from E. coli DH5α cells using the Qiagen miniprep kit and analysing with the Nanodrop machine.

Materials and Protocol

Please refer to: Minipreps for Qiagen miniprep protocol, Nanodrop Spectrophotometer for nanodrop protocol and Restriction digests for restriction digestion protocol. NOTE: 10 µl of RNAse A have been added into the current P1 buffer from Qiagen.

Result

Newcastle 020810 gel.png

Figure 1:Gel electrophoresis of the PCR products

  • Lane 1: 1kb DNA ladder
  • Lane 2: Extraction of pSB1C3 plasmid (No. 1)
  • Lane 3: Extraction of pSB1C3 plasmid (No. 2)
  • Lane 4: Extraction of pSB1C3 plasmid (No. 3)
  • Lane 5: Extraction of plasmid containing lacI (No. 1)
  • Lane 6: Extraction of pSB1AK3 plasmid containing double terminator (No. 1)
  • Lane 7: 1kb DNA ladder


pSB1C3

(No. 1)

pSB1C3

(No. 2)

pSB1C3

(No. 3)

lacI

(No. 1)

Double terminator

(No. 1)

92.1 µl/ml 110.0 µl/ml 110.5 µl/ml 246.1 µl/ml 246.7 µl/ml

Table 1: Nanodrop spectrophotometer results. Table represents the amount of plasmid present in µl/ml quantity.

Discussion

Bands around 3000 bp were observed in lanes 2, 3 and 4, thereby indicating the correct products. Lane 5 contain the LacI plasmid,therefore it should be bigger in size as compared to the double terminator plasmid which is in lane 6. Therefore lane 5 might not contain the LacI plasmid. From the nanodrop results, the ratio of 260.280 nm ranged from 1.7 to 1.85 and the concentration ranged from 92.1 µl/ml to 246.7 µl/ml. These results indicated that the DNA extracted have low RNA contamination and the samples are pure.

Conclusion

Extraction of pSB1C3 plasmid and pSB1AK3 plasmid containing double terminator have been successful.


Newcastle University logo.png    Newcastle cbcb logo.pngNewcastle Biomedicine logo.gif    Team Newcastle CEG logo.gif
Newcastle iww logo.jpg  UNIPV Pavia Logo.gif  Newcastle BBSRC.gif    Newcastle Genevision logo.png Newcastle WelcomeTrust.jpg
FaceBook Icon