The measurements were performed on cells both in the exponential and stationary phase. The resulting graphs are presented below:<br>
The measurements were performed on cells both in the exponential and stationary phase. The resulting graphs are presented below:<br>
-
[[Image:Team-SDU-denmarkBetacarotene samples with controles (exponential_phase).png |350px]]
+
[[Image:Team-SDU-denmarkBetacarotene samples with controles (exponential_phase).png |thumb|350px|left|UV-VIS measurement of beta-carotene concentration in four ''E. coli'' strains in Log phase]]
-
[[Image:Team-SDU-denmarkBetacarotene samples with controles (stationary phase).png |350px]]
+
[[Image:Team-SDU-denmarkBetacarotene samples with controles (stationary phase).png|thumb|350px|center|UV-VIS measurement of beta-carotene concentration in four ''E. coli'' strains in Log phase]]
<br>
<br>
In order to assess the results, a series of standard dilutions of beta-carotene were made. The concentrations were 1mM, 100 µM, 50 µM, 25 µM, 10 µM, 5 µM, 1 µM, 100 nM and 10 nM. The standard dilutions were also measured on the spectrophotometer. The resulting graphs are presented low: <br>
In order to assess the results, a series of standard dilutions of beta-carotene were made. The concentrations were 1mM, 100 µM, 50 µM, 25 µM, 10 µM, 5 µM, 1 µM, 100 nM and 10 nM. The standard dilutions were also measured on the spectrophotometer. The resulting graphs are presented low: <br>
<br>
<br>
-
[[Image:Team-SDU-denmarkStandart betacaroten curves.png |400px|center]]
+
[[Image:Team-SDU-denmarkStandart betacaroten curves.png |400px|thumb|center|]]
<br>
<br>
When combining the graphs of the samples and the standard dilutions, it is clear that the spectres are uniform. This similarity of the spectres indicates that the cells actually do produce beta-carotene. The graphs also give a qualitative indication of the amount of beta-carotene produced by the MG1655 and the Top10 ''E. coli'' cells. The resulting graphs are presented below: <br><br>
When combining the graphs of the samples and the standard dilutions, it is clear that the spectres are uniform. This similarity of the spectres indicates that the cells actually do produce beta-carotene. The graphs also give a qualitative indication of the amount of beta-carotene produced by the MG1655 and the Top10 ''E. coli'' cells. The resulting graphs are presented below: <br><br>