''' 1.UV-Vis determination of beta-carotene and retinal production: '''<br>
''' 1.UV-Vis determination of beta-carotene and retinal production: '''<br>
-
In this experiment cells was prepare and harvested according to protocol [https://2010.igem.org/Team:SDU-Denmark/protocols#EX1.1]. This experiment was preformed with six different strain of E. Coli:<br>
+
In this experiment cells was prepare and harvested according to protocol [https://2010.igem.org/Team:SDU-Denmark/protocols#EX1.1]. This experiment was preformed with six different strains of ''E. coli'':<br> <br>
-
wildtype Top10<br>  
+
Wild type Top10<br>  
-
wildtype MG1655<br>  
+
Wild type MG1655<br>  
-
Top10 containing PSB1A2 with K274210 constitutively active<br>  
+
Top10 containing PSB1A2 with constitutively active K274210<br>  
-
MG1655 containing PSB1A2 with K274210 constitutively active<br>  
+
MG1655 containing PSB1A2 with constitutively active K274210<br>  
-
TOP10 containing PSB1A2 with K274210 plus PSB1C3 with K343005 both under a constitutively active promotor<br>  
+
TOP10 containing PSB1A2 with K274210 and PSB1C3 with K343005, both under a constitutively active promotor<br>  
-
MG1655 containing PSB1A2 with K274210 plus PSB1C3 with K343005 both under a constitutively active promotor<br>  
+
MG1655 containing PSB1A2 with K274210 and PSB1C3 with K343005, both under a constitutively active promotor<br> <br>
-
The measurements were preformed on cells after 20 hours of growth, because the first experiment showed none or little product produced in the exponential phase. The resulting graphs is presented beneath the text.<br>
+
The measurements were performed on cells after 20 hours of growth seeing as the first experiment showed no or little product in the exponential phase. The resulting graphs are presented below:<br> <br>
[[Image: Team-SDU-denmark-Samples form top10 mg1655 and control.png |350px|]]
[[Image: Team-SDU-denmark-Samples form top10 mg1655 and control.png |350px|]]
-
<br>
+
<br><br>
-
In the spectre a sudden drop at 320 nm occurs, this cannot be explained .<br>
+
In the spectrum, a sudden drop at 320 nm occurs. This cannot be explained .<br>
-
The graph also shows that some cell material interferes with the UV-Vis measurement at the retinal has the strongest absorption, because of this some organic separation might be needed before the measurement is preformed.<br>  
+
The graph also shows that some cell material interferes with the UV-vis measurement at the retinal has the strongest absorption, because of this some organic separation might be needed before the measurement is preformed.<br>  
In order assess the results a standard dilution of beta-carotene and retinal was made and measured: 1mM, 100 µM, 50 µM, 25 µM, 10 µM, 5 µM, 1 µM, 100 nM and 10 nM. The standart dilutions was also measured on the spectrophotometer. The resulting graphs is presented beneath the text<br>
In order assess the results a standard dilution of beta-carotene and retinal was made and measured: 1mM, 100 µM, 50 µM, 25 µM, 10 µM, 5 µM, 1 µM, 100 nM and 10 nM. The standart dilutions was also measured on the spectrophotometer. The resulting graphs is presented beneath the text<br>
[[Image: Team-SDU-denmark-Beta-carotene standarts.png |390px|]]
[[Image: Team-SDU-denmark-Beta-carotene standarts.png |390px|]]

Revision as of 16:14, 25 October 2010