Team:Debrecen-Hungary/protocols/midiprep

From 2010.igem.org

(Difference between revisions)
Line 114: Line 114:
Plasmid concentration is higher, than after only one elution<br/>
Plasmid concentration is higher, than after only one elution<br/>
<html>
<html>
-
<object style="height: 190px; width: 290px" ><param name="movie" value="http://www.youtube.com/v/6z12Kww0tE0" ><param name="allowFullScreen" value="true" ><param name="allowScriptAccess" value="always" ><embed src="http://www.youtube.com/v/6z12Kww0tE0" type="application/x-shockwave-flash" allowfullscreen="true" allowScriptAccess="always" width="290" height="190" ></object>
+
<object style="height: 190px; width: 290px" ><param name="movie" value="http://www.youtube.com/v/dxv63-rBc7E" ><param name="allowFullScreen" value="true" ><param name="allowScriptAccess" value="always" ><embed src="http://www.youtube.com/v/dxv63-rBc7E" type="application/x-shockwave-flash" allowfullscreen="true" allowScriptAccess="always" width="290" height="190" ></object>
</html>
</html>
Line 124: Line 124:
Carefully discard the supernatant.<br/>
Carefully discard the supernatant.<br/>
<html>
<html>
-
<object style="height: 190px; width: 290px" ><param name="movie" value="http://www.youtube.com/v/sd8KMm1CjgY" ><param name="allowFullScreen" value="true" ><param name="allowScriptAccess" value="always" ><embed src="http://www.youtube.com/v/sd8KMm1CjgY" type="application/x-shockwave-flash" allowfullscreen="true" allowScriptAccess="always" width="290" height="190" ></object>
+
<object style="height: 190px; width: 290px" ><param name="movie" value="http://www.youtube.com/v/d2_HV8Mx0go" ><param name="allowFullScreen" value="true" ><param name="allowScriptAccess" value="always" ><embed src="http://www.youtube.com/v/d2_HV8Mx0go" type="application/x-shockwave-flash" allowfullscreen="true" allowScriptAccess="always" width="290" height="190" ></object>
</html>
</html>
Line 133: Line 133:
<html>
<html>
<left>
<left>
-
<object style="height: 190px; width: 290px" ><param name="movie" value="http://www.youtube.com/v/WexogvRd3bs" ><param name="allowFullScreen" value="true" ><param name="allowScriptAccess" value="always" ><embed src="http://www.youtube.com/v/WexogvRd3bs" type="application/x-shockwave-flash" allowfullscreen="true" allowScriptAccess="always" width="290" height="190" ></object>
+
<object style="height: 190px; width: 290px" ><param name="movie" value="http://www.youtube.com/v/0AFgNjVbFGg" ><param name="allowFullScreen" value="true" ><param name="allowScriptAccess" value="always" ><embed src="http://www.youtube.com/v/0AFgNjVbFGg" type="application/x-shockwave-flash" allowfullscreen="true" allowScriptAccess="always" width="290" height="190" ></object>
</left>
</left>
</html>
</html>

Revision as of 14:30, 24 October 2010


Contents

Scientific Background

Overview

Procedure for High Copy Number Plasmids

Materials

1. Sample material: 30 ml E. coli culture, transformed with a high copy number plasmid Harvest cultures at a density between 2.0 and 6.0 A600 units per ml bacterial culture

2. Media: The isolation method is optimized for cultures grown in LB media; other rich media may require increased volumes of Suspension-, Lysis- and Neutralization Buffer, and an additional wash step

3. Plasmid size: The isolation procedure is suitable for all plasmid sizes; lysates of larger constructs (up to 100 kb) should be cleared by filtration to avoid shearing

4. Suspension Buffer/RNase A: To dissolve the lyophilized enzyme in Suspension Buffer, pipet 1 ml of Suspension Buffer (bottle 1, black cap) into the glass vial containing the lyophilized RNase (bottle 2, black cap). Reinsert the rubber stopper and invert the vial until all lyophilizate (including any that might stick to the rubber stopper) is dissolved. Transfer the dissolved enzyme back to the Suspension Buffer bottle (bottle 1). This is enough working solution for 60 Midi preps (isolation of up to 100 μg plasmid DNA/preparation)

5. If preparing aliquots of the working solution, remember that the final concentration of RNase A in the working solution must be 100 g/ml. Reconstituted buffer is stable for 6 months is stored properly (+2 to +8°C)

6. Neutralization Buffer: Before starting, cool it down to 4°C

7. Elution Buffer: Before starting, warm up the buffer to 50°C

8. Ethanol: Use 70% ethanol. Before starting, cool it down to 4°C

Procedure

1. Centrifuge bacterial cells from 30 ml culture grown in LB medium by centrifuging for 10 min at 5000 rpm,4°C
Discard the supernatant. Carefully resuspend the pellet in 4 ml Suspension Buffer + RNase and mix well
  


2. Add 4 ml Lysis Buffer to the suspension and mix gently by inverting the tube 6 times. Incubate 2-3 min at room temperature. To avoid shearing genomic DNA, do not vortex the suspension in Lysis Buffer. To prevent release of chromosomal DNA from the cell debris, do not incubate for more than 5 minutes


3. Add 4 ml chilled Neutralization Buffer to the suspension. Immediately mix the suspension gently by inverting the tube 6 times until a homogenous suspension is formed. Incubate the tube 5 min on ice
The solution becomes cloudy and a flocculent precipitate will form


4. Clear the lysate by filtration. Put a folded filter into a funnel that has been inserted into a 50 ml plastic tube. Moisten the filter with a few drops of Equilibrium Buffer. Load the lysate onto the wet, folded filter and collect the flowthrough
The SDS precipitates with cellular debris when Neutralisation Buffer is added; this white precipitate should not be loaded onto the column. If the solution obtained after step 14 is not clear, remove the remaining precipitate by passing the solution over a folded filter


5. Mount the sealing ring to the column to fix the column in the collection tube. Insert one column into one collection tube. Equilibrate the column with 2,5 ml Equilibration Buffer. Allow the column to empty by gravity flow. Discard the flowthrough


6. Load the cleared lysate from step 4 onto the equilibrate column. Allow the column to empty by gravity flow. Discard the flowthrough


7. Wash the column with 5 ml Wash Buffer. Allow the column to empty by gravity flow. Discard the flowthrough


8. Repeat step 7 Discard flowthrough and collection tube


9. Re-insert the column into a new collection tube Elute the plasmid with 5 ml prewarmed Elution Buffer (50°C) Allow the column to empty by gravity flow The collection flowthrough contains the plasmid Elute the plasmid again with the flowthrough Allow the column to empty by gravity flow Plasmid concentration is higher, than after only one elution


10. Precipitate the eluted plasmid DNA with 3,6 ml isopropanol Total volume ~6,8 ml Divide the eluted plasmid into five 1,5 ml eppendorf tubes and one tube which contains 73 μl. Centrifuge immediately 30 min at 15000×g (rcf), +4°C. Carefully discard the supernatant.


11. Divide the 6 tubes into two groups. Wash the plasmid DNA with 1,5 ml chilled (+4°C) 70% ethanol in the first tube and afterwards wash the other two with the same ethanol. Wash the other group (3 tubes) the same way.Centrifuge 10 min at 15000×g (rcf), +4°C. Carefully remove ethanol from the tube with pipet tip.Air-dry the plasmid DNA pellet for 10 min.


12. Carefully redissolve the plasmid DNA pellet in 100 μl TE buffer.


13. Measure the concentration with NanoDrop (DNA)

Notes & troubleshooting

References

1.Birnboim, H.C. and Doly, J. (1979) A rapid alkaline lysis procedure for screening recombinant plasmid DNA. Nucl. Acids Res. 7, 1513-1522

2.Sambrook, J. et al. (1989) Molecular Cloning: A Laboratory Manual, 2nd. Edition, Cold Spring Harbour Laboratory Press

3.Ausubel, F.M. et al. (eds.) (1991) Current Protocols in Molecular Biology, Wiley Interscience, New York

Other