Team:Chiba/Project
From 2010.igem.org
(→Double Click Bacteria) |
|||
(30 intermediate revisions not shown) | |||
Line 18: | Line 18: | ||
border: 0; | border: 0; | ||
} | } | ||
+ | p{margin:10px 20px 10px;} | ||
+ | |||
</style> | </style> | ||
</html> | </html> | ||
Line 72: | Line 74: | ||
#tabs10 ul { | #tabs10 ul { | ||
margin:0; | margin:0; | ||
- | padding:2px 10px 0 | + | padding:2px 10px 0 105px; |
list-style:none; | list-style:none; | ||
} | } | ||
Line 127: | Line 129: | ||
<li><a href="https://2010.igem.org/Team:Chiba/Project"><span>Project</span></a></li> | <li><a href="https://2010.igem.org/Team:Chiba/Project"><span>Project</span></a></li> | ||
<li><a href="https://2010.igem.org/Team:Chiba/Parts"><span>Parts</span></a></li> | <li><a href="https://2010.igem.org/Team:Chiba/Parts"><span>Parts</span></a></li> | ||
- | |||
<li><a href="https://2010.igem.org/Team:Chiba/Notebook"><span>Notebook</span></a></li> | <li><a href="https://2010.igem.org/Team:Chiba/Notebook"><span>Notebook</span></a></li> | ||
<li><a href="https://2010.igem.org/Team:Chiba/Support"><span>Support</span></a></li> | <li><a href="https://2010.igem.org/Team:Chiba/Support"><span>Support</span></a></li> | ||
Line 181: | Line 182: | ||
#tabs9 ul { | #tabs9 ul { | ||
margin:0; | margin:0; | ||
- | padding:2px 10px 0 | + | padding:2px 10px 0 105px; |
list-style:none; | list-style:none; | ||
} | } | ||
Line 232: | Line 233: | ||
<ul> | <ul> | ||
<!-- CSS Tabs --> | <!-- CSS Tabs --> | ||
- | <li><a href="https://2010.igem.org/Team:Chiba/Project"><span> | + | <li><a href="https://2010.igem.org/Team:Chiba/Project"><span>Double Click System</span></a></li> |
- | <li><a href="https://2010.igem.org/Team:Chiba/System_1"><span> | + | <li><a href="https://2010.igem.org/Team:Chiba/System_1"><span>Version 1</span></a></li> |
- | <li><a href="https://2010.igem.org/Team:Chiba/System_2"><span> | + | <li><a href="https://2010.igem.org/Team:Chiba/System_2"><span>Version 2</span></a></li> </ul> |
</div> | </div> | ||
</body> | </body> | ||
Line 249: | Line 250: | ||
===<font size="5">Double Click Bacteria</font>=== | ===<font size="5">Double Click Bacteria</font>=== | ||
- | --- | + | ----- |
- | + | We’re inspired by double-click of computer’s mouse. It doesn’t react to the first click but does react when it is accompanied by the second one. This is one of the most accepted, familiarized, and proven mechanism to diminish the erroneous operation. This fail-safe technology should find various uses also in biotechnology. | |
- | + | Here is what we envision: once in a while, bacteria might receive input which wasn’t intended. But they are careful enough (they know Homo sapiens always make mistake!) so that they ignore the input for the first time. However, when they receive the two inputs in succession, they finally judge the input(s) are real, and start taking the action as programmed. Also, they are smart enough to distinguish double-clicking from the two separate (or erroneous) inputs. | |
- | + | ||
- | + | First, the circuit must distinguish the second input (stimulus) from the first one, even though they are chemically physically the same . To realize this, we need the counting device. Second, the circuit must distinguishes W-click from two separate clicks; the circuit reacts only when the first and the second input are given in short period of time. Thus, the genetic counter should be coupled with the genetic timers. After a certain time after the first input (timeout), the circuit gets back to the initial state so that the next stimulous is recognized as the first input. | |
- | + | <html> | |
+ | <center> | ||
+ | <table width="80%"><tr><td> | ||
+ | <img src="https://static.igem.org/mediawiki/2010/7/7c/Click.jpg"></td><td> | ||
+ | <object width="480" height="385"><param name="movie" value="http://www.youtube.com/v/vQbNnGbuXj0?fs=1&hl=ko_KR"></param><param name="allowFullScreen" value="true"></param><param name="allowscriptaccess" value="always"></param><embed src="http://www.youtube.com/v/vQbNnGbuXj0?fs=1&hl=ko_KR" type="application/x-shockwave-flash" allowscriptaccess="always" allowfullscreen="true" width="480" height="385"></embed></object> | ||
+ | </td></tr></table> | ||
+ | </center> | ||
+ | </html> | ||
+ | <br><br><br> | ||
- | ==< | + | ===<font size="5">The Bottom Line is...</font>=== |
- | #If there is | + | #If there is only an input, nothing happens. |
- | # | + | #Duration of the input is not the matter. The circuit cares only the number of input. |
- | # | + | #However, a certain time after the 1st input, it returns to the initial state. |
- | # | + | #Giving two inputs in the limited time the circuit get activated (gives output). |
+ | <Br><br> | ||
+ | |||
+ | ===<font size="5">Systems</font>=== | ||
+ | <html> | ||
+ | <center> | ||
+ | <table width="80%" border="0"><tr><td style="text-align:center;"> | ||
+ | <a href="https://2010.igem.org/Team:Chiba/System_1"><img src="https://static.igem.org/mediawiki/2010/d/db/Chiba_plan2_1.jpg" border="0" width="300px" /><br>version 1</a> | ||
+ | </td><td style="text-align:center;"> | ||
+ | <a href="https://2010.igem.org/Team:Chiba/System_2"><img src="https://static.igem.org/mediawiki/2010/1/1a/Chiba_Sys2.jpg" border="0" width="300px" /><br>version 2</a> | ||
+ | </td></tr></table> | ||
+ | </center> | ||
+ | </html> |
Latest revision as of 03:10, 28 October 2010
Double Click Bacteria
We’re inspired by double-click of computer’s mouse. It doesn’t react to the first click but does react when it is accompanied by the second one. This is one of the most accepted, familiarized, and proven mechanism to diminish the erroneous operation. This fail-safe technology should find various uses also in biotechnology.
Here is what we envision: once in a while, bacteria might receive input which wasn’t intended. But they are careful enough (they know Homo sapiens always make mistake!) so that they ignore the input for the first time. However, when they receive the two inputs in succession, they finally judge the input(s) are real, and start taking the action as programmed. Also, they are smart enough to distinguish double-clicking from the two separate (or erroneous) inputs.
First, the circuit must distinguish the second input (stimulus) from the first one, even though they are chemically physically the same . To realize this, we need the counting device. Second, the circuit must distinguishes W-click from two separate clicks; the circuit reacts only when the first and the second input are given in short period of time. Thus, the genetic counter should be coupled with the genetic timers. After a certain time after the first input (timeout), the circuit gets back to the initial state so that the next stimulous is recognized as the first input.
The Bottom Line is...
- If there is only an input, nothing happens.
- Duration of the input is not the matter. The circuit cares only the number of input.
- However, a certain time after the 1st input, it returns to the initial state.
- Giving two inputs in the limited time the circuit get activated (gives output).
Systems
version 1 |
version 2 |