Team:Newcastle/Gel extraction
From 2010.igem.org
(Difference between revisions)
Line 2: | Line 2: | ||
=QIAquick Gel Extraction Microcentrifuge Protocol= | =QIAquick Gel Extraction Microcentrifuge Protocol= | ||
+ | |||
# Excise the DNA fragment from the agarose gel with a clean, sharp scalpel. | # Excise the DNA fragment from the agarose gel with a clean, sharp scalpel. | ||
+ | |||
+ | {| | ||
+ | |- | ||
+ | |[[Image:Newcastle_lab_4.jpeg|thumb]] | ||
+ | |[[Image:Newcastle_lab_5.jpeg|thumb]] | ||
+ | |[[Image:Newcastle_lab_6.jpeg|thumb]] | ||
+ | |- | ||
+ | |} | ||
+ | |||
+ | {| | ||
+ | |- | ||
+ | |[[Image:Newcastle_lab_7.jpeg|thumb]] | ||
+ | |[[Image:Newcastle_lab_8.jpeg|thumb]] | ||
+ | |- | ||
+ | |} | ||
+ | |||
# Weight the gel slice and add 3 volumes of buffer QG to 1 volume of gel (100 mg ~ 100 µl). | # Weight the gel slice and add 3 volumes of buffer QG to 1 volume of gel (100 mg ~ 100 µl). | ||
# Incubate at 50°C and invert the tube gently at regular interval until the gel has completely dissolved. | # Incubate at 50°C and invert the tube gently at regular interval until the gel has completely dissolved. | ||
Line 16: | Line 33: | ||
# To elute DNA, add 30 µl of Buffer EB to the center of the QIAquick membrane and allow to stand for 1 min. | # To elute DNA, add 30 µl of Buffer EB to the center of the QIAquick membrane and allow to stand for 1 min. | ||
# Centrifuge the column for 1 min and transfer the eluate to a clean 1.5 ml micriocentrifuge tube. | # Centrifuge the column for 1 min and transfer the eluate to a clean 1.5 ml micriocentrifuge tube. | ||
+ | |||
+ | |||
+ | |||
{{Team:Newcastle/footer}} | {{Team:Newcastle/footer}} |
Revision as of 09:13, 10 August 2010
|
QIAquick Gel Extraction Microcentrifuge Protocol
- Excise the DNA fragment from the agarose gel with a clean, sharp scalpel.
- Weight the gel slice and add 3 volumes of buffer QG to 1 volume of gel (100 mg ~ 100 µl).
- Incubate at 50°C and invert the tube gently at regular interval until the gel has completely dissolved.
- After the gel has dissolved completely, check that the color of the mixture is yellow.
- Add 1 gel volume of isopropanol to the sample and mix.
- Place a QIAquick spin column in a 2 ml collection tube
- To bind DNA, apply the sample to the QIAquick column and centrifuge for 1 min.
- Discard the flow through and place the QIAquick column back into the same tube (max volume: 750 µl).
- Add 0.5 ml of Buffer QG to QIAquick column and centrifuge for 1 min. Discard the flow through and place the QIAquick column back into the same tube.
- To wash, add 0.75 ml of Buffer PE to QIAquick column and centrifuge for 1 min. Place the QIAquick column back into the same tube.
- Centrifuge the column for a further 1 min.
- Transfer the column into a clean 1.5 ml micriocentrifuge tube.
- To elute DNA, add 30 µl of Buffer EB to the center of the QIAquick membrane and allow to stand for 1 min.
- Centrifuge the column for 1 min and transfer the eluate to a clean 1.5 ml micriocentrifuge tube.