Team:Heidelberg/Project/Measurement Standard

From 2010.igem.org

(Difference between revisions)
(Methods)
(Methods)
Line 77: Line 77:
* Consumables and Chemicals
* Consumables and Chemicals
-
PerkinElmer ViewPlate, product number: 6004920
+
PerkinElmer ViewPlate, product number: 6004920<br>
-
Nunc 24 well microplate, product number: 176740
+
Nunc 24 well microplate, product number: 176740<br>
-
1x PBS (1.37mM NaCl, 0.27mM KCl, 10mM Na2HPO4, 0.2mM KH2PO4)
+
1x PBS (1.37mM NaCl, 0.27mM KCl, 10mM Na2HPO4, 0.2mM KH2PO4)<br>
-
0.05% Trypsin-EDTA, Invitrogen GIBCO, product number: 15400054
+
0.05% Trypsin-EDTA, Invitrogen GIBCO, product number: 15400054<br>
* Instruments
* Instruments
-
Leica DM IRB
+
Leica DM IRB<br>
-
Leica SP5
+
Leica SP5<br>
-
Tecan Infinite M200
+
Tecan Infinite M200<br>
-
FACS machine
+
FACS machine<br>
-
ImageJ version 1.43
+
ImageJ version 1.43<br>
==References==
==References==

Revision as of 21:05, 23 October 2010

Measurement Standard

Abstract

Introducing synthetic micro RNAs and their bindig sites to the iGEM community, we established a standard for charactarization of micro RNA binding sites. Our miMeasure plasmids normalizes knockdown of a GFP marker protein to a BFP marker protein on the same construct, thereby simplifying control measurements. The binding site can be introduced by simple cloning according to BBB standard. Fluorescent measurements can be easily conducted through plate reader experiments, FACS or microscopy.

Introduction

Micro RNAs regulate the translation of their target genes by binding to regions in the 3’ UTR that we call miRNA binding sites (ref). This miRNA binding site (BS) consists of a Xbp seed region that is perfectly matched to the miRNA, and surrounding regions that matched partially. The seed region is defined as being the minimal required basepairing at the 5’ end of the miRNA that can regulate the mRNA. Apart from the seed region, binding can be unspecific, creating bulges between miRNA and mRNA (fig). The position and properties of the bulges seem to play a role in miRNA binding and therefore knockdown efficiency.

Since we were going to use synthetic miRNA BS in our genetherapeutic approach, we had to find a way to study their effects in a standardized manner that would be comparable and reproducible.

One goal of the iGEM Team Heidelberg 2010 was to test the effects of changes in BS sequence and thereby characterize miRNA BS. To standardize our measurements of knockdown according to BS specificity, we had to come up with a new standard that is independent from the endogenous cell machinery. We decided to bring in synthetic miRNAs and engineer BS for them, simulating naturally occurring miRNAs and miRNA BS without having to worry about the effect of endogenous targets. Of course there are also differences that arise through the availability of the enzymes involved in the miRNA pathway that may differ slightly from cell to cell. Therefore, we also measured the knockdown achieved by the perfect binding site and set this as 100% knockdown efficiency. Ideally, the shRNA would be expressed stably in the cell line, but a uniform co-transfection also leads to an even distribution of shRNA into each cell.

The main idea of our measurement standard, miMeasure, was to express two nearly identical but discernable proteins, one of them tagged with a BS, the other one unregulated. These two reporters were expressed by a bidirectional CMV promoter to make sure their expression rate is identical. We used a destablilized version of GFP, dsEGFP by Clontech (ref) and a dsEBFP2 that was derived from the same sequence. Thus, we could make sure that both proteins exhibit the same synthesis and degradation properties, making them directly comparable. Hereby we can also neglect the difference between mRNA and protein knockdown and can take the fluorescence of the marker protein as a direct, linear output of mRNA knockdown. We included a BBB standard site into our plasmid, which allows to clone BS behind the GFP. If co-transfected with the corresponding shRNA, GFP will be downregulated, while BFP expression is maintained. The ratio of GFP to BFP expression can be used to conclude the knockdown efficiency (in percent, compared to perfect binding site=100% and no binding site=0%) of the BS. Having destabilized marker proteins with a turnover time of two hours enables us not only to avoid accumulation of marker proteins, which would make the knockdown harder to observe, but also to conduct time-lapse experiments. In the future, this could be for example a way to observe the activity patterns of endogenous miRNAs.

Results

Discussion

Methods

To measure GFP and BFP fluorescence, we used the Tecan infinite M200 multiprobe reader. Cells were measured in PBS on a 96-well plate one day after trasfection. Fluorescence was fist evaluated using the Leica DM IRB epifluorescence microscope. Only cells which were evenly distributed and showed fluorescence were measured.

Settings for TECAN measurements: GFP excitation: 488nm, emission: 520nm, gain: 180 BFP excitation: 405nm, emission: 450nm, gain: 140

After TECAN measurement, cells where detached from the plates. 30µl Trypsin was added to each well, incubated for ten minutes at room temperature. Cells were resuspended in 170µl PBS/BSA and replicates for each condition were pooled into 24 well plates. 200µl from each well were used for FACS measurements, 100-150µl were used for confocal microscopy.

FACS

Microscopy

Single images were obtained using the Leica TCS SP5 confocal microscope and ??? camera with the Leica AF6000 imaging software ??. GFP fluorescenc was excited by Argon 488nm laser and measured at xx-xxnm, BFP fluorescence was excited by UV laser at 405nm and measured at xx-xxnm. Pictures were taken sequencially line by line in three different channels for GFP, BFP and bright field.

Data Analysis












  • Consumables and Chemicals

PerkinElmer ViewPlate, product number: 6004920
Nunc 24 well microplate, product number: 176740
1x PBS (1.37mM NaCl, 0.27mM KCl, 10mM Na2HPO4, 0.2mM KH2PO4)
0.05% Trypsin-EDTA, Invitrogen GIBCO, product number: 15400054


  • Instruments

Leica DM IRB
Leica SP5
Tecan Infinite M200
FACS machine
ImageJ version 1.43

References

Contents