Team:Warsaw/Stage3/Results

From 2010.igem.org

Revision as of 12:18, 24 October 2010 by Mlower (Talk | contribs)

Example Tabs

BactoDHL results

BactoDHL - under the microscope

Microscopic observation of HeLa cells infected with BactoDHL confirmed the functionality of the system. During preperatics the Hirsch dye was used to enhance GFP glowing, which is a FRET-based effect (FRET - Förster Resonance Energy Transfer). The light wave emitted by the Hirsch dye additionally excites GFP, what happens only when the the distance between the two molecules is not greater than 10 nanometers. Infected HeLa cells can be seen as a mildly-glowing areas containing bright spots of GFP inside.

BactoDHL in numbers

Flow Cytometry made it possible to express in numbers what could be seen under the microscope. For each sample during preperatics lysozyme was used to prevent the adhesion of bacteria to the surface of HeLa, but 100% efficiency cannot be expected form this procedure (see fig.X - HeLa Cells incubated with GFP-producing but non-invasive Top10) The results of control experiments are as follows:

HeLa Cells incubated with non-invasive, non-transformed Top10 E. coli – no fluorescence observed.

HeLa Cells incubated with GFP-producing but non-invasive Top10. Hardly noticeable fluorescence observed.



BactoDHL-involving experiments

Up:HeLa Cells incubated with J23102+INV+LLO+GFP-transformed E. coli Top10.

HeLa Cells incubated with AraC+INV+LLO+GFP-transformed E. coli Top10.

In both cases two different “populations” of GFP can be observed, depending on two varying fluorescence levels. These represent the amounts of protein (1) still entrapped in endosome and (2) distributed to cytoplasm. This interpretation is based on the results of many previous studies indicating that the GFP is able to act as a pH sensor.

The existence of relationship between pH and levels of GFP fluorescence is a commonly known fact. The Microfluidic system was used to investigate this relationship on the FACS machine used for BactoDHL-related experiments. Microfluidic system, also termed in vitro compartmentalization (IVC) is a water-in-oil-in-water emulsion containing droplets as small as bacteria, having volumes of less than a femtolitre. Enclosing GFP in different pH buffers in such ‘beads’ provided the result without complicated transfection-based procedures.

The data analysis leads to a simple conclusion: The less acidic (closer to neutral) the pH, the stronger the GFP fluorescence. This strongly supports our theory: in the lyzosome (pH~5) weaker fluorescence of GFP is observed than in the cytosol (pH~7).

from: A.D. Griffiths, D.S. Tawfik Miniaturizing the laboratory in emulsion droplets, Trends in Biotechnology (2006) Vol.24 No.9

HeLa cells incubated with non-transformed Top10, GFP-producing Top10 and BactoDHL: percentage of GFP delivered to different compartments.

Efficiency of GFP delivery to mammalian cells cytoplasm

BactoDHL proves to be highly efficient intracellular protein delivery system.