PCR program: Touch-Down

95°C 1 min
95°C 30 sec
56°C 60 sec
72°C 30 sec
return to step 2 for 2 cycles
95°C 30 sec
54°C 60 sec
72°C 30 sec
return to step 6 for 2 cycles
95°C 30 sec
52°C 60 sec
72°C 30 sec
return to step 10 for 2 cycles
95°C 30 sec
50°C 60 sec
72°C 30 sec
return to step 14 for 2 cycles
95°C 30 sec
48°C 60 sec
72°C 30 sec
return to step 18 for 2 cycles
95°C 30 sec
46°C 60 sec
72°C 30 sec
return to step 22 for 2 cycles
95°C 30 sec
44°C 60 sec
72°C 30 sec
return to step 26 for 2 cycles
95°C 30 sec
42°C 60 sec
72°C 30 sec
return to step 30 for 2 cycles
95°C 30 sec
48°C 60 sec
72°C 30 sec
return to step 34 for 30 cycles
72°C 10 min
12°C forever