Protocol/17
From 2010.igem.org
(Difference between revisions)
(New page: {{Team:Alberta/Head}} {{Team:Alberta/navbar|project=selected}} {{Team:Alberta/beginLeftSideBar}} {{Team:Alberta/endLeftSideBar}} {{Team:Alberta/beginRightSideBar}} {{Team:Alberta/endRig...) |
|||
Line 13: | Line 13: | ||
Protocol 17: PCR | Protocol 17: PCR | ||
- | |||
- | |||
- | |||
- | |||
- | |||
- | |||
- | + | Procedure: | |
- | *PCR buffer | + | * Before you start: |
+ | ** KEEP EVERYTHING ON ICE. Put Taq back into freezer as soon as you`re done with it. DON`T put back dNTP tubes. | ||
+ | ** Reserve a thermocycler and check what size of tubes it takes. | ||
+ | ** Making a master mix conserves expensive reagents, so try to always use one. | ||
+ | ** You may have to do dilutions of your reagents in order to make them usable for PCR (ex: primers, plasmid DNA...) | ||
+ | ** DON'T PUT PRIMERS OR TEMPLATE INTO THE MASTER MIX. ADD POLYMERASE TO THE MASTER MIX LAST (after your other tubes already have template DNA and primers in them)! | ||
+ | *To add into a tube: | ||
+ | {| | ||
+ | |PCR buffer || 5ul | ||
+ | |- | ||
+ | |10uM dNTPs || 1ul | ||
+ | |- | ||
+ | |50uM MgCl2 || 2ul | ||
+ | |- | ||
+ | |Forward primer || 2.5ul | ||
+ | |- | ||
+ | |Reverse primer || 2.5ul | ||
+ | |- | ||
+ | |1ng Template || 1ul | ||
+ | |- | ||
+ | |Taq polymerase || 0.5ul | ||
+ | |- | ||
+ | |MilliQ water || 35.5ul | ||
+ | |- | ||
+ | |TOTAL || 50ul | ||
- | |||
- | |||
- | |||
- | |||
- | |||
- | |||
- | |||
- | |||
- | |||
- | |||
- | |||
- | |||
- | |||
- | |||
- | |||
[[Team:Alberta/Notebook/protocols| Back]] | [[Team:Alberta/Notebook/protocols| Back]] | ||
{{Team:Alberta/endMainContent}} | {{Team:Alberta/endMainContent}} |
Revision as of 02:17, 26 October 2010
Protocol 17: PCR
Procedure:
- Before you start:
- KEEP EVERYTHING ON ICE. Put Taq back into freezer as soon as you`re done with it. DON`T put back dNTP tubes.
- Reserve a thermocycler and check what size of tubes it takes.
- Making a master mix conserves expensive reagents, so try to always use one.
- You may have to do dilutions of your reagents in order to make them usable for PCR (ex: primers, plasmid DNA...)
- DON'T PUT PRIMERS OR TEMPLATE INTO THE MASTER MIX. ADD POLYMERASE TO THE MASTER MIX LAST (after your other tubes already have template DNA and primers in them)!
- To add into a tube:
PCR buffer | 5ul |
10uM dNTPs | 1ul |
50uM MgCl2 | 2ul |
Forward primer | 2.5ul |
Reverse primer | 2.5ul |
1ng Template | 1ul |
Taq polymerase | 0.5ul |
MilliQ water | 35.5ul |