Team:MIT mmethods
From 2010.igem.org
(Difference between revisions)
Line 29: | Line 29: | ||
<a href="#coat">1.6 PDL coating</a><br> | <a href="#coat">1.6 PDL coating</a><br> | ||
<a href="#cf">1.7 Collagen filling</a><br> | <a href="#cf">1.7 Collagen filling</a><br> | ||
- | 1.8 Cell Seeding<br> | + | <a href="#seed">1.8 Cell Seeding</a><br> |
- | 2 Protocol for Deflection Experiments<br> | + | <a href="#deflection">2 Protocol for Deflection Experiments</a><br> |
- | 2.1 Tubing Setup Details<br> | + | <a href="#tubing">2.1 Tubing Setup Details</a><br> |
- | 2.2 Adding Medium to Channels<br> | + | <a href="#medium">2.2 Adding Medium to Channels</a><br> |
- | 2.3 Connecting device to pressure valve<br> | + | <a href="#valve">2.3 Connecting device to pressure valve</a><br> |
- | 2.4 Microcontroller details<br> | + | <a href="#micro">2.4 Microcontroller details</a><br> |
</div></td><tr><td> | </div></td><tr><td> | ||
Line 108: | Line 108: | ||
<li>4. Leave all devices for 1 hour in the incubator (in the humidity box) for the gel to polymerize</li> | <li>4. Leave all devices for 1 hour in the incubator (in the humidity box) for the gel to polymerize</li> | ||
<li>5. [IMPORTANT. This protocol establishes a stable pocket of air between the two medium channels at the outlet port.] Fill channels with medium from reservoir ports (~50-100µL). Gently fill medium until the channels have been filled to the cell seeding filling ports. Do NOT fill all the way to the outlet port. Instead, be sure to leave air at the channel intersection and in the outlet port. Place a droplet of medium over the outlet port to trap the air inside. Place devices in incubator. They will be ready for cell seeding in 24hours. </li></ul><br> | <li>5. [IMPORTANT. This protocol establishes a stable pocket of air between the two medium channels at the outlet port.] Fill channels with medium from reservoir ports (~50-100µL). Gently fill medium until the channels have been filled to the cell seeding filling ports. Do NOT fill all the way to the outlet port. Instead, be sure to leave air at the channel intersection and in the outlet port. Place a droplet of medium over the outlet port to trap the air inside. Place devices in incubator. They will be ready for cell seeding in 24hours. </li></ul><br> | ||
- | <b class="bolded">Cell Seeding</b><br> | + | <b class="bolded" id="seed">Cell Seeding</b><br> |
<ul id="procedure"> | <ul id="procedure"> | ||
<li>1. Trypsinize cells, spin down (@ 1.2 rpm, 5 min), and resuspend in medium to a final concentration of 2 million cells/ml</li> | <li>1. Trypsinize cells, spin down (@ 1.2 rpm, 5 min), and resuspend in medium to a final concentration of 2 million cells/ml</li> | ||
Line 118: | Line 118: | ||
- | <div class="bodybaby">Protocol for Deflection Experiments</div><br> | + | <div class="bodybaby" id="deflection">Protocol for Deflection Experiments</div><br> |
- | <b class="bolded">Tubing Setup Details</b><br> | + | <b class="bolded" id="tubing">Tubing Setup Details</b><br> |
<ul id="procedure"> | <ul id="procedure"> | ||
<li>1. Connect the outlet port to a ‘dead end’ (a cap at the end of the tubing that prevents liquid flow); use a tapered connection.</li> | <li>1. Connect the outlet port to a ‘dead end’ (a cap at the end of the tubing that prevents liquid flow); use a tapered connection.</li> | ||
<li>2. Connect the inlet port to a syringe. <b>Note: The tubing should be sterilized.</b></li></ul> <br> | <li>2. Connect the inlet port to a syringe. <b>Note: The tubing should be sterilized.</b></li></ul> <br> | ||
- | <b class="bolded">Adding Media to Channels</b><br> | + | <b class="bolded" id="medium">Adding Media to Channels</b><br> |
<ul id="procedure"> | <ul id="procedure"> | ||
<li><b>Note: before applying pressure, we're going to add medium to all control channels; don’t want to apply the pressure to air in the control channels.</b></li> | <li><b>Note: before applying pressure, we're going to add medium to all control channels; don’t want to apply the pressure to air in the control channels.</b></li> | ||
<li>1. Fill a small syringe with medium and connect to the inlet port.</li> | <li>1. Fill a small syringe with medium and connect to the inlet port.</li> | ||
<li>2. Open the ‘dead end’ and push the syringe to fill control channel with medium.</li></ul><br> | <li>2. Open the ‘dead end’ and push the syringe to fill control channel with medium.</li></ul><br> | ||
- | <b class="bolded">Connecting Device to Pressure Valve</b><br> | + | <b class="bolded" id="valve">Connecting Device to Pressure Valve</b><br> |
<ul id="procedure"> | <ul id="procedure"> | ||
<li>1. Find the microcontroller; connect tubing from pressure valve to appropriate inlet of microcontroller – (a small hole on the left or right side, pick a side depending on how you want to control the pressure).</li> | <li>1. Find the microcontroller; connect tubing from pressure valve to appropriate inlet of microcontroller – (a small hole on the left or right side, pick a side depending on how you want to control the pressure).</li> | ||
Line 135: | Line 135: | ||
<li>4. Use the buttons on the microcontroller to set the pressure program.</li> | <li>4. Use the buttons on the microcontroller to set the pressure program.</li> | ||
<li>5. Always start testing with low pressure. After 25 PSI, connectors can no longer contain the pressure. </li></ul><br> | <li>5. Always start testing with low pressure. After 25 PSI, connectors can no longer contain the pressure. </li></ul><br> | ||
- | <div class="bodybaby">Microcontroller details</div><br> | + | <div class="bodybaby" id="micro">Microcontroller details</div><br> |
<ul id="procedure"> | <ul id="procedure"> | ||
Inlets: | Inlets: |
Revision as of 03:54, 15 October 2010
Bacterial Construction Protocol
Bacterial Experimental Protocol
Phage western blot
Mammalian Protocol
Microfluidic stress
Materials
mammalian protocol |
The Mammalian team focused on creating a pressure-sensitive promoter and creating a standard protocol for mammalian genes.
1 HTD Preparation Protocol 1.1 PDMS Mixture Preparation 1.2 PDMS Pouring 1.3 PDMS Baking 1.4 PDMS-Device Punching and Bonding 1.5 PDMS Device Bonding 1.6 PDL coating 1.7 Collagen filling 1.8 Cell Seeding 2 Protocol for Deflection Experiments 2.1 Tubing Setup Details 2.2 Adding Medium to Channels 2.3 Connecting device to pressure valve 2.4 Microcontroller details |
HTD Preparation Protocols (adapted from Yannis, Alisha) PDMS Mixture Preparation Materials
Procedure
PDMS Pouring
PDMS Baking
PDMS-Device punching and Bonding
PDMS Device Bonding - Plasma Treatment
PDL Coating
Collagen Filling Material
Procedure
Cell Seeding
Protocol for Deflection Experiments Tubing Setup Details
Adding Media to Channels
Connecting Device to Pressure Valve
Microcontroller details
|