Team:HokkaidoU Japan/Notebook/August13
From 2010.igem.org
(Difference between revisions)
(→反応液の組成) |
(→ミニプレで増えなかったパーツのPCR) |
||
Line 1: | Line 1: | ||
{{Template:HokkaidoU_Japan}}<div class="linkbar"><div class="prev">[[Team:HokkaidoU_Japan/Notebook/August12|August 12]]</div>[[Team:HokkaidoU_Japan/Notebook|Notebook]]<div class="next">[[Team:HokkaidoU_Japan/Notebook/August16|August 16]]</div></div> | {{Template:HokkaidoU_Japan}}<div class="linkbar"><div class="prev">[[Team:HokkaidoU_Japan/Notebook/August12|August 12]]</div>[[Team:HokkaidoU_Japan/Notebook|Notebook]]<div class="next">[[Team:HokkaidoU_Japan/Notebook/August16|August 16]]</div></div> | ||
- | = | + | =PCR of parts which didn't amplify well via mini prep= |
- | == | + | ==Composition of Reaction Solution== |
{|class="protocol" | {|class="protocol" | ||
|- | |- | ||
Line 36: | Line 36: | ||
|} | |} | ||
- | == | + | ==Removal of Primers== |
- | # | + | # Added 150 uL of TE to 50 uL of PCR product, each |
- | # | + | # Transfered into Microcon YM-10 filter and cetrifuged for 20 min at 14000G |
- | # | + | # Much of the solution remained so centrifuged for aditional 10 min |
- | # | + | # Measured the amount left |
- | # | + | ## It was 140 uL so centrifuged again for 10min |
+ | # And again | ||
+ | # Finally DNA solution was reduced to 19 uL so we added 31 uL to make final volume of 50 uL | ||
+ | |||
+ | ==Electrophoresis== | ||
- | |||
[[Image:HokkaidoU Japan 20100813a.jpg|200px|right|thumb|]] | [[Image:HokkaidoU Japan 20100813a.jpg|200px|right|thumb|]] | ||
- | # | + | |
- | # | + | # Added 0.4 uL of 6x Sample Buffer to 1 uL of DNA solution and electrophoresed it. |
- | * | + | # At the same time add added 2 uL of 6x Sample Buffer to 10 uL of flow trough and centrifuged |
- | * | + | * Used marker [https://2010.igem.org/Image:HokkaidoU_Pictures_DNA_Marker.png pUC119/''Hin''f] |
- | * | + | * It was confirmed that DNA was amplified by PCR |
+ | ** Between marker bands of 543 bp and 1330 bp PCR product band of 700 bp was visible | ||
+ | * Due to negligence (electrophoresis for 45min), flow through with primers flowed through and exited gel | ||
<div style="clear:both"> | <div style="clear:both"> |
Revision as of 07:16, 20 September 2010
PCR of parts which didn't amplify well via mini prep
Composition of Reaction Solution
Reagent | Amount |
---|---|
Autoclaved DW : | 33 uL |
10x PCR buffer : | 5 uL |
2 mM dNTPs : | 5 uL |
25 mM MgSO4 : | 3 uL |
EX-F primer : | 1 uL |
PS-R primer : | 1 uL |
KOD plus Neo : | 1 uL |
Template (1-18F) : | 1 uL |
Total : | 50 uL |
Removal of Primers
- Added 150 uL of TE to 50 uL of PCR product, each
- Transfered into Microcon YM-10 filter and cetrifuged for 20 min at 14000G
- Much of the solution remained so centrifuged for aditional 10 min
- Measured the amount left
- It was 140 uL so centrifuged again for 10min
- And again
- Finally DNA solution was reduced to 19 uL so we added 31 uL to make final volume of 50 uL
Electrophoresis
- Added 0.4 uL of 6x Sample Buffer to 1 uL of DNA solution and electrophoresed it.
- At the same time add added 2 uL of 6x Sample Buffer to 10 uL of flow trough and centrifuged
- Used marker pUC119/Hinf
- It was confirmed that DNA was amplified by PCR
- Between marker bands of 543 bp and 1330 bp PCR product band of 700 bp was visible
- Due to negligence (electrophoresis for 45min), flow through with primers flowed through and exited gel