{{Template:HokkaidoU_Japan}}<div class="linkbar"><div class="prev">[[Team:HokkaidoU_Japan/Notebook/August12|August 12]]</div>[[Team:HokkaidoU_Japan/Notebook|Notebook]]<div class="next">[[Team:HokkaidoU_Japan/Notebook/August16|August 16]]</div></div> | {{Template:HokkaidoU_Japan}}<div class="linkbar"><div class="prev">[[Team:HokkaidoU_Japan/Notebook/August12|August 12]]</div>[[Team:HokkaidoU_Japan/Notebook|Notebook]]<div class="next">[[Team:HokkaidoU_Japan/Notebook/August16|August 16]]</div></div> | ||
- | + | =ミニプレで増えなかったパーツのPCR= | |
- | + | ==反応液の組成== | |
- | + | {|class="protocol" | |
- | + | ||
- | {| | + | |
|- | |- | ||
|style="text-align:right;"| Autoclaved DW : | |style="text-align:right;"| Autoclaved DW : |
Revision as of 04:54, 19 September 2010
ミニプレで増えなかったパーツのPCR
反応液の組成
Autoclaved DW : | 33 uL |
10x PCR buffer : | 5 uL |
2 mM dNTPs : | 5 uL |
25 mM MgSO4 : | 3 uL |
EX-F primer : | 1 uL |
PS-R primer : | 1 uL |
KOD plus Neo : | 1 uL |
Template (1-18F) : | 1 uL |
Total : | 50 uL |
primerの除去
- PCR products 50 uLにTE 150 uLを加え,ろ過用のチューブ(Microcon YM-10)に入れ,14000Gで20分間遠心した.
- 十分量ろ過されていなかったので,もう10分遠心した
- ろ液を測ると140 uLだっため,さらに10分遠心した
- なんかまだびみょうだったからもう10分遠心した
- DNAを含む溶液が19 uLになったため,31 uLのTEを加え総量50 uLにした
電気泳動
- primerなどを除去したDNA溶液 1 uLに6x Sample Buffer 0.4 uLを加え,泳動した
- 同時に,ろ液 10 uLに6x Sample Buffer 2 uLを加えたものも遠心した
- マーカーはpUC119/Hinf
- PCRでDNAが増幅されたことが確認された(543 bpと1330 bpの間に約700 bpのPCR産物)
- 油断して45分間泳動したため,同時に流したprimerを含むろ液は流れた