Team:BCCS-Bristol/Wetlab/characterising ratio

From 2010.igem.org

(Difference between revisions)
(0 - 10mM Assay)
 
(6 intermediate revisions not shown)
Line 1: Line 1:
{{:Team:BCCS-Bristol/Header}}
{{:Team:BCCS-Bristol/Header}}
-
 
-
 
-
 
=Characterising the Ratio Method=
=Characterising the Ratio Method=
Line 8: Line 5:
==Motivation==
==Motivation==
 +
{{:Team:BCCS-Bristol/newtoc}}
Our experiments of signal visibility in soil highlighted the need to calibrate our signal - allowing us to determine whether high fluorescence readings were due to high Nitrate levels or large colonies.  
Our experiments of signal visibility in soil highlighted the need to calibrate our signal - allowing us to determine whether high fluorescence readings were due to high Nitrate levels or large colonies.  
-
To solve this problem we implemented our ratio method; transforming our 'E. coli' with both our new biobrick and another biobrick from the parts registry BBa_J04450 - coding for constitutive RFP production. This then allows GFP readings to be compared against a baseline RFP reading, with the overall ratio of fluorescent proteins being used as the measure of Nitrate in solution or soil.
+
To solve this problem we implemented our ratio method; transforming our ''E. coli'' with both our new BioBrick and another BioBrick from the parts registry BBa_J04450 - coding for constitutive RFP production. This then allows GFP readings to be compared against a baseline RFP reading, with the overall ratio of fluorescent proteins being used as the measure of Nitrate in solution or soil.
 +
 
==Double Transformations==
==Double Transformations==
-
We started by transforming 'E. coli' MG1655 with our new biobrick and one encoding constitutive RFP production following standard transformation methods - mixing 100μL of MG1655 with 2μL of BBa_K381001 and 2μL of BBa_J04450. Colonies from this transformation were then used in all subsequent assays here.
+
We started by transforming 'E. coli' MG1655 with our new BioBrick and one encoding constitutive RFP production following standard transformation methods - mixing 100μL of MG1655 with 2μL of BBa_K381001 and 2μL of BBa_J04450. Colonies from this transformation were then used in all subsequent assays here.
 +
 
==0 - 10mM Assay==
==0 - 10mM Assay==
Having made our double transformants the next step was to characterise their response to Nitrate. We began by examining this between 0 and 10mM of Potassium Nitrate (in 2mM steps). 5mL solutions of LB and Potassium Nitrate were made up in sterilins and inoculated with the same colony of MG1655s. These were then left overnight at 37°C and their fluorescence analysed using the photo-spectrometer the next morning. This gave results as follows (Where data is missing, colonies produced neither GFP nor RFP, thus were discounted as failures, note how this highlights the usefulness of the double transform method in stopping false negatives):
Having made our double transformants the next step was to characterise their response to Nitrate. We began by examining this between 0 and 10mM of Potassium Nitrate (in 2mM steps). 5mL solutions of LB and Potassium Nitrate were made up in sterilins and inoculated with the same colony of MG1655s. These were then left overnight at 37°C and their fluorescence analysed using the photo-spectrometer the next morning. This gave results as follows (Where data is missing, colonies produced neither GFP nor RFP, thus were discounted as failures, note how this highlights the usefulness of the double transform method in stopping false negatives):
-
 
{| border="1"
{| border="1"
Line 57: Line 56:
|2.76224
|2.76224
|}
|}
-
 
As is evident from the graph below there is a clear trend of an increase in GFP/RFP with increasing Nitrate levels, indicating our ratio solution did work as anticipated.
As is evident from the graph below there is a clear trend of an increase in GFP/RFP with increasing Nitrate levels, indicating our ratio solution did work as anticipated.
[[Image:GFPRFP0to10 blobs.png|centre|500px]]
[[Image:GFPRFP0to10 blobs.png|centre|500px]]
 +
==0 - 2mM Assay==
==0 - 2mM Assay==
-
Having established our ratio method worked between 0 - 2mM KNO3, we were keen to check whether it worked at levels more relevant to our particular project. Consultation with farmers established typical Nitrate levels in soil lay began 0 - 2mM, thus we decided to characterise the double transformants further in this range.  
+
Having established our ratio method worked between 0 - 10mM KNO3, we were keen to check whether it worked at levels more relevant to our particular project. Consultation with farmers established typical Nitrate levels in soil lay began 0 - 2mM, thus we decided to characterise the double transformants further in this range.  
As before, 5mL solutions of LB and Potassium Nitrate were set up, inoculated, and left overnight at 37°C. We then analysed their fluorescence using the photo-spectrometer, yielding the following results:
As before, 5mL solutions of LB and Potassium Nitrate were set up, inoculated, and left overnight at 37°C. We then analysed their fluorescence using the photo-spectrometer, yielding the following results:
-
 
{| border="1"
{| border="1"
Line 114: Line 112:
|}
|}
-
Again this allowed us to plot a graph indicating behaviour [insert graph!] that shows a clear upward trend in ratio with Nitrate, indicating our ratio method works well not only across a broad range, but also within the Nitrate levels that are important for this project. Further, this data allowed us to formulate an equation linking the fluorescence to Nitrate levels [insert equation!]
+
Again this allowed us to plot a graph indicating behaviour that shows a clear upward relationship between ratio of fluorescent proteins and Nitrate, indicating our ratio method works well not only across a broad range, but also within the Nitrate levels that are important for this project.
 +
 
 +
[[Image:Ratio0to2 quadratic fit.png|centre|500px]]
 +
 
 +
Finally, this data allowed us to formulate an equation linking the fluorescence to Nitrate levels:
 +
 
 +
[[Image:Equation.PNG|centre]]
 +
 
 +
 
 +
=Conclusions=
 +
 
 +
We were extremely pleased with these results. Not only had we solved the problem of misleading GFP results, but also formed an equation linking the readings that would be picked up by a farmer with his tractor to actual Nitrate levels, something that would be essential when creating a marketable product.

Latest revision as of 19:10, 27 October 2010

Characterising the Ratio Method

Motivation

Contents

Our experiments of signal visibility in soil highlighted the need to calibrate our signal - allowing us to determine whether high fluorescence readings were due to high Nitrate levels or large colonies.

To solve this problem we implemented our ratio method; transforming our E. coli with both our new BioBrick and another BioBrick from the parts registry BBa_J04450 - coding for constitutive RFP production. This then allows GFP readings to be compared against a baseline RFP reading, with the overall ratio of fluorescent proteins being used as the measure of Nitrate in solution or soil.


Double Transformations

We started by transforming 'E. coli' MG1655 with our new BioBrick and one encoding constitutive RFP production following standard transformation methods - mixing 100μL of MG1655 with 2μL of BBa_K381001 and 2μL of BBa_J04450. Colonies from this transformation were then used in all subsequent assays here.


0 - 10mM Assay

Having made our double transformants the next step was to characterise their response to Nitrate. We began by examining this between 0 and 10mM of Potassium Nitrate (in 2mM steps). 5mL solutions of LB and Potassium Nitrate were made up in sterilins and inoculated with the same colony of MG1655s. These were then left overnight at 37°C and their fluorescence analysed using the photo-spectrometer the next morning. This gave results as follows (Where data is missing, colonies produced neither GFP nor RFP, thus were discounted as failures, note how this highlights the usefulness of the double transform method in stopping false negatives):

Nitrate (mM) GFP RFP GFP / RFP
0 0.045 0.0205 0.45556
2 0.061 0.1057 1.73279
4 n/a n/a n/a
6 0.0522 0.1128 2.16092
8 n/a n/a n/a
10 0.0429 0.1185 2.76224

As is evident from the graph below there is a clear trend of an increase in GFP/RFP with increasing Nitrate levels, indicating our ratio solution did work as anticipated.

GFPRFP0to10 blobs.png


0 - 2mM Assay

Having established our ratio method worked between 0 - 10mM KNO3, we were keen to check whether it worked at levels more relevant to our particular project. Consultation with farmers established typical Nitrate levels in soil lay began 0 - 2mM, thus we decided to characterise the double transformants further in this range.

As before, 5mL solutions of LB and Potassium Nitrate were set up, inoculated, and left overnight at 37°C. We then analysed their fluorescence using the photo-spectrometer, yielding the following results:

Nitrate (mM) ratio test 1 ratio test 2 ratio test 3 average
0 n/a 0.70025 0.54227 0.62126
0.4 1.17228 n/a 1.10214 1.13721
0.8 n/a 1.34615 1.27687 1.31151
1.2 n/a n/a n/a n/a
1.6 n/a 1.83442 1.61957 1.727
2.0 1.41866 n/a 2.414 1.91633

Again this allowed us to plot a graph indicating behaviour that shows a clear upward relationship between ratio of fluorescent proteins and Nitrate, indicating our ratio method works well not only across a broad range, but also within the Nitrate levels that are important for this project.

Ratio0to2 quadratic fit.png

Finally, this data allowed us to formulate an equation linking the fluorescence to Nitrate levels:

Equation.PNG


Conclusions

We were extremely pleased with these results. Not only had we solved the problem of misleading GFP results, but also formed an equation linking the readings that would be picked up by a farmer with his tractor to actual Nitrate levels, something that would be essential when creating a marketable product.