Team:BCCS-Bristol/Wetlab/K381001 Characterisation
From 2010.igem.org
(One intermediate revision not shown) | |||
Line 1: | Line 1: | ||
{{:Team:BCCS-Bristol/Header}} | {{:Team:BCCS-Bristol/Header}} | ||
- | |||
- | |||
- | |||
=Characterising the Biobrick= | =Characterising the Biobrick= | ||
{{:Team:BCCS-Bristol/newtoc}} | {{:Team:BCCS-Bristol/newtoc}} | ||
- | With our | + | With our BioBrick made, we then needed to establish whether it worked, and over what range. We began by checking simply whether it responded to nitrate at all. Then, having determined that it did, conducted a more detailed assay across the range of nitrate levels for which the BioBrick is most sensitive. |
- | + | ||
- | + | ||
+ | Having established the BioBrick was definitely switched on by 20mM of KNO3, we wanted to conduct a broader test of its behaviour across a range of different nitrate levels | ||
+ | <br/><br/><br/><br/> | ||
==Initial Tests== | ==Initial Tests== | ||
- | To begin with we simply wanted to determine whether the | + | To begin with we simply wanted to determine whether the BioBrick worked as expected - producing GFP in the presence of |
nitrates, but not without. | nitrates, but not without. | ||
Line 33: | Line 30: | ||
|} | |} | ||
- | The cultures were then left in the 37°C shaker overnight and examined the next morning. We were pleased to note that the culture exposed to nitrate was visibly green whilst the one without was not, suggesting our new | + | The cultures were then left in the 37°C shaker overnight and examined the next morning. We were pleased to note that the culture exposed to nitrate was visibly green whilst the one without was not, suggesting our new BioBrick worked at least at the most basic ‘on/ off’ level. |
==More detailed characterisation: 0 - 10mM assay== | ==More detailed characterisation: 0 - 10mM assay== | ||
Line 39: | Line 36: | ||
===Experiment=== | ===Experiment=== | ||
- | Our next step was to set up and assay examining the | + | Our next step was to set up and assay examining the BioBrick's behaviour between 0 – 10 mM of Potassium Nitrate at 2mM intervals. The same colony of MG1655 containing BBa_K381001 was used to inoculate six 5mL tubes of LB at varying nitrate levels as listed below. This was repeated twice to allow the results to be averaged. |
{| border="1" | {| border="1" | ||
Line 72: | Line 69: | ||
===Data=== | ===Data=== | ||
- | |||
As can be seen in fig. 1, the level of GFP increased steadily with nitrate, with the exact figures in table 1. | As can be seen in fig. 1, the level of GFP increased steadily with nitrate, with the exact figures in table 1. | ||
- | |||
- | |||
[[Image:Picture 036.jpg|thumbnail|left|400px]] | [[Image:Picture 036.jpg|thumbnail|left|400px]] | ||
Line 117: | Line 111: | ||
|} | |} | ||
- | + | <br/><br/><br/><br/><br/><br/><br/> | |
- | + | ||
- | + | ||
- | + | ||
- | + | ||
- | + | ||
- | + | ||
- | + | ||
- | + | ||
- | + | ||
- | + | ||
===Graphs=== | ===Graphs=== | ||
This data allowed us to construct graphs illustrating the trend in increased GFP production with increase in nitrate. The first images below show the raw data from the photo-spectrometer, and the graphs constructed from it. | This data allowed us to construct graphs illustrating the trend in increased GFP production with increase in nitrate. The first images below show the raw data from the photo-spectrometer, and the graphs constructed from it. | ||
- | |||
- | |||
- | |||
[[Image:Gfp assay things.png|centre|600px]] | [[Image:Gfp assay things.png|centre|600px]] | ||
- | |||
We then used this data to generate a graph showing the average increase in GFP production, as illustrated below: | We then used this data to generate a graph showing the average increase in GFP production, as illustrated below: | ||
- | |||
[[Image:GFPChar0to10.png|centre|500px]] | [[Image:GFPChar0to10.png|centre|500px]] | ||
- | |||
Unfortunately, because we only ran two repeats, we cannot be certain whether the downward curve of the graph is true behaviour or the result of one the 10mM readings being extremely low | Unfortunately, because we only ran two repeats, we cannot be certain whether the downward curve of the graph is true behaviour or the result of one the 10mM readings being extremely low | ||
Line 148: | Line 126: | ||
==Conclusions== | ==Conclusions== | ||
- | From this data we are pleased to report that not only does our | + | From this data we are pleased to report that not only does our BioBrick definitely work - particularly within the range that is relevant to our project - but also it is very well characterised, making it extremely accessible to other users of the parts registry in the future. |
Latest revision as of 19:07, 27 October 2010
iGEM 2010
Characterising the Biobrick
Contents |
Having established the BioBrick was definitely switched on by 20mM of KNO3, we wanted to conduct a broader test of its behaviour across a range of different nitrate levels
Initial Tests
To begin with we simply wanted to determine whether the BioBrick worked as expected - producing GFP in the presence of nitrates, but not without.
Two 5mL overnights were set up, one without any nitrogen and one with 20mM of Potassium Nitrate KNO3, made up according to the table below. This level was chosen as previous work by the Edinburgh 2009 iGEM team had shown the promoter strongly active by this point.
Nitrate (mM) | LB (mL) | KNO3 (μL) |
0 | 5 | 0 |
20 | 5 | 102 |
The cultures were then left in the 37°C shaker overnight and examined the next morning. We were pleased to note that the culture exposed to nitrate was visibly green whilst the one without was not, suggesting our new BioBrick worked at least at the most basic ‘on/ off’ level.
More detailed characterisation: 0 - 10mM assay
Experiment
Our next step was to set up and assay examining the BioBrick's behaviour between 0 – 10 mM of Potassium Nitrate at 2mM intervals. The same colony of MG1655 containing BBa_K381001 was used to inoculate six 5mL tubes of LB at varying nitrate levels as listed below. This was repeated twice to allow the results to be averaged.
Nitrate (mM) | LB (mL) | KNO3 (μL) |
0 | 5 | 0 |
2 | 5 | 10 |
4 | 5 | 20 |
6 | 5 | 30 |
8 | 5 | 40 |
10 | 5 | 50 |
Data
As can be seen in fig. 1, the level of GFP increased steadily with nitrate, with the exact figures in table 1.
Nitrate (mM) | GFP level test 1 | GFP level test 2 | Average GFP level |
0 | 0.0242 | 0.0289 | 0.0266 |
2 | 0.0752 | 0.1143 | 0.0948 |
4 | 0.1042 | 0.1197 | 0.1120 |
6 | 0.1248 | 0.1234 | 0.1241 |
8 | 0.1179 | 0.1396 | 0.1288 |
10 | 0.0631 | 0.1186 | 0.0909 |
Graphs
This data allowed us to construct graphs illustrating the trend in increased GFP production with increase in nitrate. The first images below show the raw data from the photo-spectrometer, and the graphs constructed from it.
We then used this data to generate a graph showing the average increase in GFP production, as illustrated below:
Unfortunately, because we only ran two repeats, we cannot be certain whether the downward curve of the graph is true behaviour or the result of one the 10mM readings being extremely low
Conclusions
From this data we are pleased to report that not only does our BioBrick definitely work - particularly within the range that is relevant to our project - but also it is very well characterised, making it extremely accessible to other users of the parts registry in the future.