Team:UPO-Sevilla/Notebook/08 09

From 2010.igem.org

(Difference between revisions)
Line 51: Line 51:
       <p>By the end of the day, the aforementioned issues are all fixed.</p>
       <p>By the end of the day, the aforementioned issues are all fixed.</p>
 +
 +
 +
    <a class="return_button" href="/Team:UPO-Sevilla/Notebook/08_06" title="Go to 6th of August"><span>Go to 6th of August</span></a>
 +
 +
    <a class="next_button" href="/Team:UPO-Sevilla/Notebook/08_10" title="Go to 10th of August"><span>Go to 10th of August</span></a>
 +
 +
    <div class="clear"></div>
     <a class="return_button" href="/Team:UPO-Sevilla/Notebook" title="Notebook"><span>Return to Notebook</span></a>
     <a class="return_button" href="/Team:UPO-Sevilla/Notebook" title="Notebook"><span>Return to Notebook</span></a>

Revision as of 12:12, 24 October 2010

August, 9th

Assembly Team

We analyzed plaques spread the day before; it looked like if the bacteria could not grow. There were only three red colonies (negatives) in a plaque. Those devices had promoter and were assembled in high copy vectors. This is why we thought that the high expression of the devices could be harmful for bacteria. We analyzed the digestions in agarose gel to verify it. Al most all the digestions were well made and we only had to repeat two.

In order to avoid that fact again, we assembled devices including promoters in low copy vectors. Like in before cases, we used different vectors depending of the resistance of the origin vectors we need. It is summed up down:

  • pSB4K5: (1+2) + (4)
  • pSB4C5: (1+2) + (7+2)
  • pSB3T5: (11) + (19) // (12) + (19)
  • pSB3C5: (11+2) + (13+3) // (12+2) + (13+3) // (11+2) + (16+3) // (12+2) + (16+3) // (1+2) + (16+3)

It was made the necessary digestions and we left ligation over night at 13ºC on average.

Digestion: 2+5+3 with BamI-PstI. We started the following devices (3A method): 7+2+28; 2+6+2+5+3; 2+18; 28+3; 2+4+2+6; 2+28; 18+3: digestion, ligation and transformation.

DryLab Team

Modeling:

Simulation issues concerning concentrations' stability fixed. Concentrations behave as expected.

Beginning of E-coli movement modeling, basing on tumbling and straight swim.

First implementation of a random movement is successful.

Simulation of bacterial movement in an environment with Chemoattractants started. Bacteria move towards the concentration gradient, but they tend to move futher away once they reach the highest concentration point. Besides, when bacteria approach a side of the recipient they are in, they usually experience troubles coming back.

By the end of the day, the aforementioned issues are all fixed.

Go to 6th of August Go to 10th of August
Return to Notebook

Footer