<li><b>Note: before applying pressure, we're going to add medium to all control channels; don’t want to apply the pressure to air in the control channels.</b></li> | <li><b>Note: before applying pressure, we're going to add medium to all control channels; don’t want to apply the pressure to air in the control channels.</b></li> | ||
<li>1. Fill a small syringe with medium and connect to the inlet port.</li> | <li>1. Fill a small syringe with medium and connect to the inlet port.</li> | ||
- | <li>2. Open the ‘dead end’ and push the syringe to fill control channel with medium.</li></ul> | + | <li>2. Open the ‘dead end’ and push the syringe to fill control channel with medium.</li></ul><br> |
+ | <b class="bolded">Connecting Device to Pressure Valve</b><br> | ||
+ | <ul id="procedure"> | ||
+ | <li>1. Find the microcontroller; connect tubing from pressure valve to appropriate inlet of microcontroller – (a small hole on the left or right side, pick a side depending on how you want to control the pressure).</li> | ||
+ | <li>2. Pick an appropriate outlet tubing from the microcontroller and attach to the inlet of your device (Note: tape device to microscope for ease of attachment).</li> | ||
+ | <li>3. Turn on the gas, turn on the valve and set the pressure to an appropriate number (anything under 10 is good)</li> | ||
+ | <li>4. Use the buttons on the microcontroller to set the pressure program.</li> | ||
+ | <li>5. Always start testing with low pressure. After 25 PSI, connectors can no longer contain the pressure. </li> | ||
Revision as of 03:32, 15 October 2010
Bacterial Construction Protocol
Bacterial Experimental Protocol
Phage western blot
Mammalian Protocol
Microfluidic stress
Materials
mammalian protocol |
The Mammalian team focused on creating a pressure-sensitive promoter and creating a standard protocol for mammalian genes.
1 HTD Preparation Protocol 1.1 PDMS Mixture Preparation 1.2 PDMS Pouring 1.3 PDMS Baking 1.4 PDMS-Device punching and Bonding 1.5 PDMS Device Bonding 1.6 PDL coating 1.7 Collagen filling 1.8 Cell Seeding 2 Protocol for Deflection Experiments 2.1 Tubing Setup Details 2.2 Adding Medium to Channels 2.3 Connecting device to pressure valve 2.4 Microcontroller details |
HTD Preparation Protocols (adapted from Yannis, Alisha) PDMS Mixture Preparation Materials
Procedure
PDMS Pouring
PDMS Baking
PDMS-Device punching and Bonding
PDMS Device Bonding - Plasma Treatment
PDL Coating
Collagen Filling Material
Procedure
Cell Seeding
Protocol for Deflection Experiments Tubing Setup Details
Connecting Device to Pressure Valve
|