Team:ETHZ Basel/Modeling
From 2010.igem.org
Molecular Modeling Overview
In order to support wet laboratory experiments and to create a test bench for the information processing part, a molecular model of E. lemming was created. This goal was achieved by implementing and combining deterministic molecular models of the individual parts.
Implementation of molecular models
The core component of E. lemming is the fusion of one light-sensitive protein (LSP?) to a protein of the chemotaxis pathway (Che?). Upon change of wavelength of light pulses, this component will dimerize with the corresponding light-sensitive protein (LSP?'), which is linked to an anchor protein, bound to an anchor (plasmid). The result is a change of the spatial localization of Che? and perturbation of the chemotaxis pathway, which ultimately leads to a different tumbling/directed flagellar movement state ratio.
Individual molecular models
In a first step, we implemented individual deterministic molecular models of subdevices.
- Light switch: based upon the light-sensitive dimerizing Arabidopsis proteins PhyB and PIF3.
- Chemotaxis: two similar models of the chemotaxis receptor pathway.
- Movement: a statistical model of E. coli movement, determined by distribution of input bias.
Combined molecular models
The next step, combination of the individual molecular models to a comprehensive model of E. lemming was achieved in two substeps:
- Light switch - Chemotaxis: used to provide support for wet laboratory.
- Light switch - Chemotaxis - Movement: complete molecular model.
Support for wet laboratory
To create the biological implementation of E. lemming, the parts of the core components had to be chosen in an order to improve chances to result in a functioning ensemble. By using the combined molecular models for in silico evaluation of the best possible parts, it was possible to reduce the amount of different combinations to be tested.
Evaluation results have showed, that molecular modeling and experimental biology can collaborate to gain new insight for both perceptions of the problem.
Support for information processing
In order to adjust the controller to have optimal light pulse rates, the combined molecular model has been used to determine the corresponding time constants.
Evaluation results provide further information how this has been accomplished.
Test bench for information processing
In order to create a first test bench for the information processing pipeline, the combined molecular models have been used to create and evaluate the controller. By providing an input port for light pulse and an output port for movement, it was possible to close the loop and simulate the whole system.