Team:VT-ENSIMAG/ResultS

From 2010.igem.org

Revision as of 19:18, 17 August 2010 by Gaelle (Talk | contribs)


VT-ENSIMAG over VT campus long.png

Select Agent Result




DNAside.png

Home

Our team

Sequence screening

The software: GenoTHREAT

Tests and Results

Screening of the iGEM registry

PCR fusion primer

Lab notebook

Safety

Media Links

Comments

SAIC.jpeg

Mitre.jpeg


The software launched on our 184 unmodified sequences succeed for 98% of the sequences. Over the 82 Select Agent sequences, all were correctly flagged. On the non select agent sequences, 4 were false hits.

Amino-acid results

If only amino-acid sequence were screened, 95% of sequences would have been correctly screened. 6% of select agent sequences would not have been flagged, and 4% of non select agent sequences would have been wrongly flagged.

Nucleotid results

Just one sequence over the 102 non select agent sequences would have been flagged with only nucleotide sequences, and that sequence is also flagged by amino_acid screening. But 3 select agent sequences would not have been flagged (4%) whithout taking into account the amino-acid result.

Conclusion

These results show the need to screen both amino-acid and nucleotide sequences. Screening amino-acid could add false positive result, but each screening flagged dangerous sequences that are not flagged by the other one.