Kit Components
- Component A, DMAO: 2x100 µL, 5 mM in DMSO
- Component B, EthD-III: 2x150 µL, 2 mM in DMSO
Preparation of Live and Dead Bacterial Suspensions as Controls
- Grow 4 mL cultures of your bacteria to late log phase in nutrient broth.
- Prepare two tubes of 1 mL of the bacteria culture in Eppendorf tubes and centrifuge at 10,000 × g for 10–15 minutes.
- Remove the supernatant and resuspend the pellet of one tube in 0.3 mL of 0.85% NaCl solution and another tube in 1 mL of 0.85% NaCl.
- Add 0.7 mL isopropyl alcohol into the tube with 0.3 mL of 0.85% NaCl and mix well (final concentration of isopropyl alcohol: 70%) for preparing dead bacteria.
- Incubate both samples at room temperature for 1 hour, mixing every 15 minutes.
- Pellet both samples by centrifugation at 10,000 × g for 10–15 minutes.
- Resuspend the pellets in 1 mL of 0.85% NaCl and centrifuge again as in step 1.6.
- Determine the optical density at 670 nm (OD670) for a 3 mL aliquot of the bacterial suspensions in glass or acrylic absorption cuvettes (1 cm pathlength).
- Use live and dead bacteria at your desired concentration for staining experiments shown below.
Staining Bacteria in Suspension
- Combine one volume of Component A and two volumes of Component B in a microcentrifuge tube, mix thoroughly and add 8 volumes of 0.85% NaCl solution to derive 100X dye solution.
- For each 100 uL of your bacteria sample and live and dead bacteria control suspensions, add 1 uL of the dye mixture.
- Mix thoroughly and incubate at room temperature in the dark for 15 minutes.
- Trap 5 µL of the stained bacterial suspension between a slide and an 18 mm square coverslip.
- Observe under a fluorescence microscope equipped with any of the filter sets as below.
Selection of Optical Filters
Longpass and dual emission filters useful for simultaneous viewing of DMAO and EthD-III stains
Omega Filters: XF25, XF26, XF115
Chroma Filters: 11001, 41012, 71010
Bandpass filters for viewing DMAO alone
Omega Filters: XF22, XF23
Chroma Filters: 31001, 41001
Bandpass filters for viewing EthD-III alone
Omega Filters: XF32, XF43, XF102, XF108
Chroma Filters: 31002, 31004, 41002, 41004
Adapted from: http://www.openwetware.org/images/b/b9/Cell_Death_Assay.pdf