Team:LMU-Munich/Notebook/Protocols/22 Ligation
From 2010.igem.org
Line 4: | Line 4: | ||
source: OpenWetWare: http://openwetware.org/wiki/DNA_Ligation | source: OpenWetWare: http://openwetware.org/wiki/DNA_Ligation | ||
- | + | <b>Materials</b> | |
+ | |||
Reagents | Reagents | ||
Line 31: | Line 32: | ||
The insert to vector molar ratio can have a significant effect on the outcome of a ligation and subsequent transformation step. Molar ratios can vary from a 1:1 insert to vector molar ratio to 10:1. It may be necessary to try several ratios in parallel for best results. | The insert to vector molar ratio can have a significant effect on the outcome of a ligation and subsequent transformation step. Molar ratios can vary from a 1:1 insert to vector molar ratio to 10:1. It may be necessary to try several ratios in parallel for best results. | ||
- | Method | + | |
+ | |||
+ | <b>Method</b> | ||
1. Add appropriate amount of deionized H2O to sterile 0.6 mL tube | 1. Add appropriate amount of deionized H2O to sterile 0.6 mL tube |
Latest revision as of 09:34, 21 September 2010
source: OpenWetWare: http://openwetware.org/wiki/DNA_Ligation
Materials
Reagents
Equipment
Vortex
Procedure
10μL Ligation Mix
Larger ligation mixes are also commonly used
Calculating Insert Amount
{\rm Insert\ Mass\ in\ ng} = 6\times\left[\fracTemplate:\rm Insert\ Length\ in\ bpTemplate:\rm Vector\ Length\ in\ bp\right]\times{\rm Vector\ Mass\ in\ ng}
The insert to vector molar ratio can have a significant effect on the outcome of a ligation and subsequent transformation step. Molar ratios can vary from a 1:1 insert to vector molar ratio to 10:1. It may be necessary to try several ratios in parallel for best results.
1. Add appropriate amount of deionized H2O to sterile 0.6 mL tube
2. Add 1 μL ligation buffer to the tube.
Vortex buffer before pipetting to ensure that it is well-mixed.
Remember that the buffer contains ATP so repeated freeze, thaw cycles can degrade the ATP thereby decreasing the efficiency of ligation.
3. Add appropriate amount of insert to the tube.
4. Add appropriate amount of vector to the tube.
5. Add 0.5 μL ligase.
Vortex ligase before pipetting to ensure that it is well-mixed.
Also, the ligase, like most enzymes, is in some percentage of glycerol which tends to stick to the sides of your tip. To ensure you add only 0.5 μL, just touch your tip to the surface of the liquid when pipetting.
6. Let the 10 μL solution sit at 22.5°C for 30 mins
7. Denature the ligase at 65°C for 10min
8. Dialyze for 20 minutes if electroporating
9. Use disks shiny side up
10. Store at -20°C
Ligation
Method