(4 intermediate revisions not shown) |
Line 1: |
Line 1: |
- | {{Biotec_Dresden/Header}}
| |
- | <html>
| |
- | <body>
| |
| | | |
- | Preparing a 96-well plate for HHL assay
| |
- |
| |
- | 1. Set-up
| |
- |
| |
- | Column1: 180µl LB-medium + 20µl H2O
| |
- | Column2: 180µl cells + 20µl H2O
| |
- | Column3: 200µl cells in 0.01nM HHL
| |
- | Column4: 200µl cells in 0.1nM HHL
| |
- | Column5: 200µl cells in 1nM HHL
| |
- | Column6: 200µl cells in 10nM HHL
| |
- | Column7: 200µl cells in 50nM HHL
| |
- | Column8: 200µl cells in 100nM HHL
| |
- | Column9: 200µl cells in 200nM HHL
| |
- | Column10: 200µl cells in 500nM HHL
| |
- | Column11: 200µl cells in 1000nM HHL
| |
- | Column12: 200µl cells in 2000nM HHL
| |
- |
| |
- | 2. Pipetting scheme
| |
- |
| |
- | 2.1. Stock solutions
| |
- |
| |
- | Final con. / µM Stock used / µM Vol. of stock / µl Vol. of water / µl
| |
- | 150 15000 12 1188
| |
- | 15 150 120 1080
| |
- | 1.5 15 120 1080
| |
- | 0.15 1.5 120 1080
| |
- | 0.015 0.15 120 1080
| |
- |
| |
- | 2.2. 94-well plate
| |
- |
| |
- | The volumes below are sufficient for pipetting four well plates at a time.
| |
- |
| |
- | Final con. / nM Stock used / µM Vol. of stock / µl Vol. of water / µl
| |
- | 0.01 0.015 4.8 715.2
| |
- | 0.1 0.015 48 672
| |
- | 1 0.15 48 672
| |
- | 10 0.15 480 240
| |
- | 50 1.5 240 480
| |
- | 100 1.5 480 240
| |
- | 200 15 96 624
| |
- | 500 15 240 480
| |
- | 1000 15 480 240
| |
- | 2000 150 96 624
| |
- |
| |
- | Pipet 20µl of the above concentrations into the corresponding wells and add 180µl of cell suspension right before the measurement of fluorescence.
| |
- |
| |
- |
| |
- | 3. Tecan plate reader
| |
- |
| |
- | Start the machine 20 minutes in advance and heat the chamber to 37°C. Put in the plate and start the measurement with the following setting:
| |
- |
| |
- | • Measure OD at 612 nm
| |
- | • Measure fluorescence with an excitation wavelength of 485nm and an emission wavelength of 485nm for both GFP and YFP
| |
- | • Shake
| |
- | • Repeat measurements every 5min for 3 hours
| |
- |
| |
- | 4. Data processing
| |
- |
| |
- | • Normalize the data by dividing all fluorescence data by the corresponding optical density
| |
- | • Subtract the obtained value of the reference column (column 2) from the calculated relative fluorescence of the wells containing HHL
| |
- | • Plot the fluorescence data over the time
| |
- |
| |
- |
| |
- |
| |
- | </body>
| |
- | </html>
| |
- |
| |
- | [[Category:BIOTEC Dresden/Protocol|AHL assay]]
| |
- | {{Biotec_Dresden/Bottom}}
| |