Team:METU Turkey Software/test

From 2010.igem.org

(Difference between revisions)
Line 134: Line 134:
overflow: auto;
overflow: auto;
}
}
 +
.content2 .text p{background:white;
 +
color:#fff;}
.content2 .text p span {
.content2 .text p span {
font-size: 11px;
font-size: 11px;

Revision as of 15:49, 27 October 2010

Team

METU Turkey Software is an interdisciplinary team of 8 students and 3 advisors from various backgrounds such as Molecular Biology, Bioinformatics, Computer Engineering and Computer Education and Instructional Technology. We have put our knowledge and experience in our fields together to bring a much needed solution to a daily problem in field of synthetic biology for iGEM 2010

Tolga Can

Tolga Can received his PhD in Computer Science at the University of California at Santa Barbara in 2004. He is currently an Assistant Professor of the Department of Computer Engineering, Middle East Technical University, Ankara, Turkey. His main research interests are in bioinformatics, especially prediction and analysis of protein-protein interaction networks, and statistical methods such as graphical models and kernel methods.

Yeşim Aydın-Son

Yeşim, has received her M.D in 1999 from HÜTF, Ankara and completed her Ph.D at University of TN, Knoxville on Genome Science and Technology in 2006. After working as a research fellow at City of Hope National Medical Center, Duarte,CA , she has recently accepted her current position at METU Informatics Institute as an Assistant Professor of Medical Informatics. She is also the acting coordinator of the Bioinformatics Graduate Program in METU. Main focus of her research is Genomic Biomarker discovery and applications of biomarker research in Personalized Medicine . Her research group is working on building a new integrated application for genome wide association of SNP biomarkers and discovery of genes and pathways related to diseases, where SNP genotyping data from both microarray and next generation sequencing experiments can be analyzed in all-in-one step.

Ömer Nebil Yaveroğlu

Content here

Burak Yılmaz

I am a recent graduate of METU Molecular Biology and Genetics department and now studying towards my masters degree on Molecular Bioengineering at METU. My interest in synthetic biology did start during my undergraduate years and after graduation I started up the Sentegen company which is the first biotechnology based company focused on synthetic biology in Turkey. I continue my research and training in synthetic biology while also contributing to the development of the field in my country. We need new scientific revolutions to solve huge problems of life and emerging field of synthetic biology is best candidate for biotechnological revolution. I am interested in synthetic biology applications, along with Lab-on-a-Chip devices for molecular biology techniques, and we are designing gene synthesis chips to produce biobricks - raw materials of synthetic garage biology- faster and cheaper. I enjoy snowboarding, cycling and write poems.

Muhammad Akif Ağca

Content here

Cihan Taştan

2010 is the last year for me as B.S degree at Molecular Biology and Genetics department. Moreover, I am studying at Computer Engineering as my minor department. My research will be on Scientist position at Cancer and Virology Relationship (Let's say Viral Oncology) by integrating novel technices of Bioinformatics and Synthetic Biology approaches. This is my second year at iGEM.

Hassan Salehe Matar

Ascended up the hills of Kilimanjaro, crossed over the savannah of Serengeti and finally landed on the country of Istanbul my name is Hassan Salehe. I'm a final year undergraduate student at the Department of Computer Engineering, Middle East Technical University. In Metu Turkey Software I'm a database administrator and a core Software developer. I'm interested in software development, database management, Computer networks and Bioiformatics I do marathon, I like swimming and I'm fond of action movies.Oh, I was about to forget to tell you that I also like traveling. Thanks!

Ayub Rokhman Wakhid

From the country of thousand islands, across the ocean he came to Ankara. Now he is finishing his undergraduate study at the Department of Computer Education and Instructional Technology, Middle East Technical University. This is the first time he joined IGEM. He is in design team in Metu Turkey Software. He has interest in animation, web development, and instructional technologies.

Muhammad Fakhry Syauqy

A senior undergraduate student of Computer Education and Instructional Technology at Middle East Technical University. He came far away from Indonesia to Ankara, Turkey, to make a great leap on his life. His role in this team is designer. Together with Ayub, they designs the team's wiki, poster. He is interested in 2D and 3D designing, web developing and animation. He loves playing football and working with computer. His motto is "Possibilities are limitless"

Saygın Karaaslan

Yener Tuncel

I have graduated from METU Molecular Biology and Genetics department and just started the Bioinformatics Graduate Program this fall. My main research interests is in systems biology, and its applications. Currently I am focused on genome wide association of SNP biomarkers, where we will utilize systems biology approaches for discovering disease gene and pathway associations after highthrough-put genotyping studies. During the course of our research on the iGEM project this summer as a Molecular Biologist I worked on the standardization of the parts information for our applicaiton database. Also, as a Bioinformatician in training, contributed to the development of the algorithms for the BioGuide software. Besides research, I develop educational tools for biology and bioinformatics education and getting used to do couples dancing.

Motivation

Since 2008, we have been participating in iGEM as METU ( Middle East Technical University) wet-lab team, and each year we have noticed the increasing number of teams participating, along with an increase in biobricks entries at partregistry.org. While having more choices of biobricks to choose from is incredible, searching for and choosing the appropriate parts is becoming a challenge. This year during the construction process of iGEM biobrick parts for our new project, we felt the need for an application to find interacting parts based on an input/output model to design the genetic constructs. Using a specialized software for searching the parts registry to find possible biobricks to include into our construct would be much easy, fast and accurate than manual. We have shared our need with a group of friends who are software engineers, and initiated the METU_Turkey_SOFTWARE team where we worked together over this summer to build the BIO-Guide software.

Scope and Future Aspects

The partregistry.org is a continuously growing collection of standard genetic parts that can be mixed and matched to build synthetic biology devices and systems. The Registry is based on the principle of "get some, give some". Registry users benefit from using the parts and information available in the Registry for designing their own genetically engineered biological systems. In exchange, the expectation is that Registry users will contribute back to the information and the data on existing parts and will submit new parts they have designed in order to improve this community resource.

As an expanding database partregistry.org needs to be more organized and the standardization template needs to be improved. Additionally, the potential of multiple ways of using each part in different construct combination brings out the necessity for an application to search through the database. BioGuide is the first designed software that organizes over 1000 parts in partregistry.org as possible atomics parts to build new biological device and systems for specific input and outputs based on graph theory. The requirement of similar applications and software tools are now inevitable in the emerging field of synthetic biology. The innovative approach that makes the partregistry.org easy to use for synthetic biology applications is the collection of standardized parts that can be used in any combination with minimal effort under one database. But while working on our algorithm to search for possible combinations of parts depending on the given input and output, we have realized that present standards are inadequate and parts registry form must be improved.

In very near future a new format for parts registry form is needed and few additional features should be implemented to have more control on the database. We are planning to suggest a new format and features for the parts registry based on the survey results we have received. And planning to build the next version of Bioguide based on the revised parts registry form. Along with using new parts registry standards we will be improving the algorithm, so that the software can search through more complex relations and returns all possible functional constructs.

Project Introduction

As the field of Synthetic Biology is on the rise, iGEM is growing up very fast and the number of parts in the parts registry is increasing with the addition of more complex parts each day. After facing some difficulty while running our algorithms on the parts registry, the need for more effective standardization of parts entry was apparent. We have investigated the information on parts in iGEM’s 2010 distribution and reorganized the information on the parts registry forms according to the needs of our algorithm. Then we have used graph theoretic modeling to visualize the relations between iGEM Parts and to standardize the representation of the parts as much as possible by graph theoretical methods. This helped us to find input output relations between the parts. Furthermore, our program BioGuide is now able to provide alternative pathways to construct the most reliable and functional Biobrick devices with respect to given inputs and expected outputs as a guide to Biobricks parts registry.

Notebook

Download

Collaboration

Part Registry Survey

Click here to go to survey page..


Results

(including responses between 10th -22nd of Oct 2010)

General Profile of Participants

  • The following teams are dedicated as collaborators with more than 60% team participation are
    • INSA-Lyon
    • Lethbridge
    • WashU
    • ...
    • ...
    • ...
  • Out of 244 participants between 10 to 22.10.2010, 57% of the participant had scientific degrees from B.Sc to Professor and 18% had graduate degrees. 18% of participants are enrolled in their teams as either Instructors or Advisors.
  • 95 teams have responded to the survey while we are still waiting to hear from 33 teams. 74% teams participated with one or more members to the survey.
  • 75% of participants were interested with synthetic biology field for academic purposes.

Browsing the Registry of Standard Parts

  • 56% of participants think that it is not easy to search for the parts in Registry of Standard Parts. Many comments indicate a need for a better search engine and more flexible keyword search options, especially excepting aliases. Also many are longing for recognizable parts names, which will ease searching with keyword.

Partnership with Google and enforcing standardized parts names are suggested

As a global organization iGEM can offer the Parts Registry in different languages and more illustrations describing how the system works.

Content of Registry of Standard Parts

  • 57% of participants agree that the number of parts registered in the Registry of Standard Parts is not enough for their projects.
  • 55% of participants think that there are enough and useful parts distributed in iGEM Plates that we can use in our projects.

Even though most agree the number of parts in the registry is impressive, still they find it limited when it comes to design different devices for diverse applications especially in different species other than E. Coli. Participants believe that if there are more functional standardized parts, especially protein coding sequences and promoter-RBS , they can design devices according to the needs of the community instead of designing what can simply be assembled into a device.

Encouraging development of vectors and standards for new species and new standardized parts in different research areas is suggested.

Enforcing submission of right DNA sequences and working conditions for each part is suggested.

Few recommend expanding iGEM into a collaborative effort rather than an undergraduate tournament, which will increase the number and the diversity of the parts designed and submitted all throughout the year.

Submission to the Parts Registry

  • 52% of participants said that they have not encountered difficulties during submitting parts. Even though participants are satisfied with the web interface of the registry, most complains about the pSB1C3 as the new standard plasmid to submit DNA.
  • 71% of participants are like minded with our team's opinion, which is that The nomenclature of part IDs such as construct, device, composite parts, protein generator, is confusing as there is no consensus on how to use them correctly.

Terminology and categorization used on iGEM’s Parts Registry should be re-described and correct use of terminology should be enforced during the submission process.

  • 75% of participants agree that different, specified submission interfaces should be designed for contructs, promoter, RBS, CDS and terminals is needed during Registry of Standard Parts. But, there are very strong and valid arguments against it such as, losing the flexibility of the registry will not allow future submission of unclassified parts.

We suggest keeping the parts submission interface as is, until these concerns are addressed.

  • 75% of participants agree that Out-dated, un-available and not-characterized parts in the Registry of Standard Parts should be removed to an archive after the consent of the designer.

“It would be great to see some sort of organization like this! I agree that unavailable parts should be followed up on and removed if necessary. I also think that parts which are not sufficiently documented should be highlighted in some way. Once these parts are identified, teams can actively characterize them as part of their projects or as side projects.”

“Think about these things: (i) who decides when a part is out-dated, and how can that person know that an old part cannot have a novel use in the future? (ii) likewise, an uncharacterized part may be both characterized and used in the future”

We suggest building a backup system, such as an archive, to sort out the rarely used, un-available and un-categorized parts until they are in line with the enforced standards.

  • 91% of participants have same opinion with us, which is that standardization of the nomenclatures used for each different composition of parts is necessary.

Standards that should be enforced and Additional New Standards

According to our survey, from high rated to low, these standards have been rated which has been used while assigning a name to parts

  • 33% Type of part
  • 17% Input
  • 17% Output
  • 14% Version
  • 10% Year
  • 9% Group

Along with above, having short recognizable part names along with function and performance , Genbank/EMBL link and organism information is important.

  • 93% of participants have said that for the parts that are marked as “WORKS” distinguishing the parts with quantitative experimental validation vs parts without this information is important. Most participants have encountered with similar problems about parts that don’t work under their lab conditions or works but not they were claimed for.
  • 89% of participants have same opinion with us, which is that iGEM should sub-categorize the “WORKS” comment into 1) “Quantitative” for parts which are characterized with experiments and 2) “Qualitative” for parts which are not characterized will be an appropriate measure for standardization of Biobrick database.

In order to overcome these problems we suggest enforcing the working conditions title for the registry entrance, in order to collect quantitative experimental details on submitted parts, which might slow down the registration process but will definitely increase the quality of the database.

  • 61% of participants agree that POPS (Polymerase Per Second) should be assigned to every part or biobricks with a promoter, where appropriate. - 57% of participants have been agree that RIPS (Ribosome per Second) should be assigned to every part or biobricks with a RBS brick.

Though most participants agree the need for POPS and RBS information , they are concerned about the workload it would bring to individual labs.

“To do this, the Registry need to define a reliable and easy method of determining the PoPS for teams to use. However, I would say that there are better systems for quantifying promoter output than PoPS, and they should be used instead, if possible”.

  • 67% of participants have thought that entering POPS information should not be mandatory while submitting new parts. Similarly, 65% of participants disagree that entering RIBS information should be mandatory while submitting new parts

Even though the researchers feeling the need for this information they are shying away from requesting it as a mandatory title for parts registry as it would be difficult for underfunded and inexperienced groups to perform these measurements.

We strongly suggest starting a forum on how to quantify the performance of promoters and genes to bring an easy to measure standard for the efficiency of the parts. Additionally iGEM should the responsibility and provide the measurements for the each promoter and gene included in the distributions. The second choice would be even better in terms of standardization as all the measurement will be performed by one center under similar conditions and with experienced researchers, which will allow user to compare and contrast the efficiencies of the parts more accurately.

  • 82% of participants have thought that information on working conditions of the parts should be mandatory while submitting new parts. Most find submiting the detailed experimental information and working conditions is crucial and even easier than submitting measurements of POPS or RBS.

Definitions you would like to see at the Registry of Standard Parts

  • Transcriptional efficiency 13%
  • Protein lifetime 10%
  • Ribosome binding efficiency 10%
  • mRNA lifetime 9%
  • Translation initiation and efficiency 9%
  • Protein concentration 9%
  • Cooperative effects with other molecules 9%
  • Protein-DNA binding rates and efficiencies 8%
  • RNA polymerase affects 8%
  • System copy count 8%
  • Protein multimerization 6%

Additional titles includes: Catalytic rates and affinities for substrates, leakiness of promoter in lack of stimulus, POPS at various inducer/repressor concentrations.

Efficiency of the Database Entries

  • 86% of participants would like to see a ranking/rating system for the parts by the other iGEM users which will be one indication of if a part is working and how well in different laboratories. Few had concerns about how well the rating system will work for rarely used parts while the widely used parts would even more popular due the the rating system. Still many believes this would be one futher towards a peer-reviewed quality control system for the parts.
  • 61% of participants agreed that parts should be updated regularly by the designers, where most agreed at least when there is new information on the parts. It has also been suggested to give permission to all the users of that part for updating information.
  • 73% of participants have been agree with us that excluding the low ranking parts or the parts with negative feedback from the future plates will increase efficiency of the system. The major concern about excluding any part is losing the variety of parts in the database. Few recommends excluding only the parts that are not working.

“Efficiency shouldn't be top priority in a database. First and foremost, data is the top priority. Excluding those parts would make the system more efficient”

“Some parts may be rare or new and have low efficiency, but can be very important! Getting rid of them would eliminate any chance of improvement to these parts, which not only a qualifier for an iGEM gold medal, but also one of the focuses of biobricks.”

We suggest excluding the parts not-working, low rated or with negative feedbacks from the annual distribution plates but still archive them and make their data available through the parts registry. So the while the individuals labs are receiving plates with higher rated, fully working parts for their projects, anyone who wants to work on a more exotic part can search through the achieves and re-vitalize the parts stored there. The challenge of re-vitalization of parts can be encouraged as an collaborative effort.

New Options for the Parts Registry Database

  • 96% of participants are like minded with us that it will be useful to have a link out to the gene/protein information of the parts and - %97 of participants have been agree that they would like to know if a part is also involved in known biological pathways.

For receiving pathway information more participants have voted for NCBI Cog (59%) than KEGG pathways (38%) when the responses for both has been distributed among the choices according to response rates. Adding the blast option to the parts registry has also been suggested to locate parts of interest. We are sure all of us would like to see gene-protein and pathway information if these information was integrated into the database and offered automatically for each entry in the database.

We are planning to provide this information about the parts to all parts registry users as a build-in option in the next version of BioGuide in iGEM 2011.

NEW PARTS REGISTRY FORM SUGGESTED FOR THE NEW STANDARDS

Link out to the form

Design

Code

Human Practices

Material

User Guide

Safety

Methods

Part Extraction Standards

All information about the parts that are essential in experimental setup of iGEM projects has been utilized. The information for the parts available provided with all three 384 well plates in Spring 2010 distribution have been standardized. Our standardization criteria have been discussed in detail under Database Standardization. ER diagram has been generated which simply describes the organization of the data. Around 70% of the parts information has been fetched by the custom parsing code from XML and Excel files provided by iGEM. Rest of the data had to be collected and organized manually as the organization of these data cannot be standardized to generate an algorithm. This step was one of the most time consuming steps in our project. For each construct and Biobrick the information collected was; Activity, Inducer, Activator, Repressor and Inhibitor for promoters and Inducer, Activator, Repressor and Inhibitor information valid for synthesized molecules (mostly proteins and RNA fragments etc.)

Combination

Rules (Image Combinations) In order to build our input/output relations graphs first we run our algorithm on the real combination dataset which contains all few thousand different possible combinations of the biobricks. But after performing all combinations for the first few hundred biobricks application’s rate slowed downed tremendously, which also become very time consuming for displaying biobricks graphs. To overcome this bottleneck we have developed a new strategy, where we have only used the construct combinations of the biobricks distributed within the plates. Moreover, according to information gathered from the subparts of the constructs distrubuted, we also collected the subpart assembly order, such as 1st: promoter, 2nd:rbs, 3rd:coding seq, any internal parts and the Last: terminator. Each specific Biobrick type has been assigned a number as a unique image ID from 1 to 19. Gathering the information on subparts was not a direct forward process. ImageID assembly orders for each construct has been used to extract the type information for each subpart with that construct. This innovative approach helped us to reveal 400 possible brick combinations present within the 3x384 well plates distributed by iGEM in Spring 2010.

Supporting Tools

Future Plan

Database Standardization

Two main focuses of our project was the organization of the available information about Biobricks on iGEM’s website and development of a software application to help synthetic biologists at the experimental set-up level by providing all available construct combinations for any given input and output relations ,which they can utilize for their own project.

Normalization and re-organization of the part information at iGEM’s web site was needed in order to develop our application, which will automatically search the possible construct combinations. For the organization and analysis of the Biobricks, we used part info for Spring 2010 distribution. The information on all three 384 well plates distributed by iGEM scrutinized and checked individually to specify the standards available and needed. iGEM is providing so many parts within a hierarchical way, but there is no order in the information flow and no common standards. Furthermore, the information bulk is being used in an ineffective manner. Some of the parts distributed are known to be nonfunctional. Web pages for parts contain lots of information, but majority of them, are again not ordered. Moreover, some additional information had to be removed or replaced in such a way that the information for parts can be used effectively. And removal of the redundant bulk information related with parts at iGEM’s web site had been recommended for future.

Although, the final standardization, which we have suggested is not for general public use and it was urgently needed in order to satisfy the needs of our algorithm. But, still it will be a valuable resource, since it summarizes the basic information about the parts.

As the first step to build the proposed standardization template, the headings selected related to parts are listed on Table 1. Submission of part IDs for individual parts is an accepted and quite valuable way of tracking information. Although, every part has unique partID, for every part there is a need to assign unique part names as official iGEM names. Part names will have an important role as they will be providing the short description about the part, which synthetic biologists can immediately recognize and utilize during the construction of unique Biobricks. Additionally unique part names will be helpful to identify the devices with more than one Biobrick in their constructs. Assignment of unique and distinct names for parts describing their nature and content will be helpful to researchers for the recognition of and search for the parts.


Headings Selected From Previous Entry Forms for Indication of Standardized Information

=========================================

PartID:

PartName:

Bricks:

BrickIDs:

ImageIDs:

RFC10:

RFC21:

RFC23:

RFC25:

=========================================

Table 1: The table above basically describes and designates qualities of parts which identifies their compositions and demonstrates the status of previously assigned standards. PartID refers to the unique ID number for parts including atomic parts and assemblies. PartName refers to the given unique names to parts. Bricks, refers to the shortcut names which specifies atomic parts. ImageIDs, refers to individual or combination of numbers that are assigned by us. RFCs refers to the states of parts based on RFC standards.

iGEM both provides individual, atomic parts and pre-combined constructs such as devices and systems. Availability of combined constructs is important to the researchers as combining individual bio-bricks one at a time will be very time consuming. These previously merged constructs, serve as the repository for puzzle and they can be used for different purposes. Up to date the largest and most trustworthy source, for synthetic biology and its components, is iGEM’s parts registry. In 2010, iGEM provided over 1000 parts that have initiated many projects. Having more atomic parts available in the iGEM’s repository, will lead to the design of more complex and robust constructs, and we would have a better chance to design different constructs for unique purposes. Also, for the parts that are already available, extra steps needs to be taken for the quality control and surveillance of these products. The quality control of the information for the parts is essential for the future of iGEM and synthetic biology. Even though we have found pre-determined RFC standards useful and included those to our standardized template, some individual parts still requires re-organization of the information as RFC standards alone for the functionality of parts, does not satisfy the needs for wet lab biologists.

Without a question there is an urgent need to build a distinct and specific database well organized with its own standards for synthetic biology; however, development of such a database is not an easy task.


Contact Information of Part Owners and Qualitative Group Comments about Parts

=========================================

Designers: Mail:

GroupFavorite:

StarRating:

Parameters:

=========================================

Table 2: The above table simply depicts information about possessors of parts and their contact information and the popularity of the parts for groups. Parameters heading, refers distinctive experimental details unique to the usage of parts which should be decided by groups.

Second step for building the standardized template was to get the phylogenic information about the parts development process which includes the name of the group, designer and contact information, along with the comments from the group on the parts they have submitted. Contact information is especially important for iGEM as other groups who need extra information about the available part can reach to the required information. Even though contacting with the designers of the individual parts which are available is highly encouraged by iGEM, unavailability of contact information points at out the fact that iGEM’s parts registry needs strong re-organization in order to serve to the synthetic biology community properly.

Additionally, the “group favorite” and “starRating” fields are also important for individual evaluation of the parts, which doesn’t get the deserved attention from the iGEM groups. “Group Favorite” defines the confidence on the part by the designer group. “StarRating” defines the related part in terms of popularity and usage efficiency among the groups. According to our observations, most groups are not aware of either of the fields or they are used incorrectly or ineffectively. For example for a part with a full reporter which is known to be functional and gives precise and expected results the StarRating should be at least 2 stars, but for most of the parts in 2010 distribution, it is very difficult to observe a part whose “StarRating” is above one. For quick determination of functionality of the parts these two evaluations are important so they have been included in the proposed standardization template. But, as they were not properly used up to now for the re-organization of the parts information during the development of our software application we had to include all parts to our queries regardless of their evaluations based on “Group Favorites” and “ StarRatings”

Second step for building the standardized template was to get the phylogenic information about the parts development process which includes the name of the group, designer and contact information, along with the comments from the group on the parts they have submitted. Contact information is especially important for iGEM as other groups who need extra information about the available part can reach to the required information. Even though contacting with the designers of the individual parts which are available is highly encouraged by iGEM, unavailability of contact information points at out the fact that iGEM’s parts registry needs strong re-organization in order to serve to the synthetic biology community properly.

Additionally, the “group favorite” and “starRating” fields are also important for individual evaluation of the parts, which doesn’t get the deserved attention from the iGEM groups. “Group Favorite” defines the confidence on the part by the designer group. “StarRating” defines the related part in terms of popularity and usage efficiency among the groups. According to our observations, most groups are not aware of either of the fields or they are used incorrectly or ineffectively. For example for a part with a full reporter which is known to be functional and gives precise and expected results the StarRating should be at least 2 stars, but for most of the parts in 2010 distribution, it is very difficult to observe a part whose “StarRating” is above one. For quick determination of functionality of the parts these two evaluations are important so they have been included in the proposed standardization template. But, as they were not properly used up to now for the re-organization of the parts information during the development of our software application we had to include all parts to our queries regardless of their evaluations based on “Group Favorites” and “ StarRatings”


Input and Output Characteristics of Parts

=========================================

Parameters:

-Input:

• Promoter:

• Activity:

• Inducer:

• Activator:

• Repressor:

• Inhibitor:

• Promoter2:

• Activity:

• Inducer:

• Activator:

• Repressor:

• Inhibitor:

-Output:

• Reporter:

• Reporter2:

• Regulator:

• Inducer:

• Activator:

• Repressor:

• Inhibitor:

• Regulator2:

• Inducer:

• Activator:

• Repressor:

• Inhibitor:

-Working Condition:

=========================================

Table 3: The table above elaborately describes the input relations based on promoters and the output products based on the functional genes and RNAs which are included within the parts. Working condition simply describes any influencing factor or circumstance which is directly related with the functional properties of parts.

Third part of our standardization template includes parameters of contingent input and output elements. These parameters are classified into two groups for simplicity as presented on Table 3. This final part of the standardization template includes the upmost important information about the Biobricks that are required for the BioGuide Software to run its searching algorithm.

Briefly, BioGuide application is designed to catch the input and output relations of individual parts to examine possible Biobricks pathways for specific input and output queries. In other words, at pre-experimental stage, it helps wet lab biologists to design their unique constructs by revealing possible alternative options for pre-determined purposes, along with the primary paths. Our ultimate goal is to improve the algorithm designed for iGEM 2010 and present a new version of the BioGuide in iGEM 2011, which will provide optimum design of constructs for predetermined parameters.

Most of the parts are composed of functional and nonfunctional constructs which are formed by atomic parts. And every part should carry the information for all of its atomic parts within itself. The “input” heading actually stands for promoters. Parts with one or more promoters can be found at iGEM’s Parts Registry. Along with the information on which and how many promoters a part might have, the activity level of promoters are also important to distinguish between a constitutively active promoter or a promoter activated by specific physiological processes or states etc. This information was crucial for us to dissect in order to run our algorithm as it directly affects which inputs can activate the devices or the systems.

Throughout our investigations on the Parts Registry, we found out that much of the terminology was being used ambiguously. Although this might not be vital for synthetic biologists, it is still endeavoring to understand the function of certain regulatory elements which also becomes a time consuming task for the researcher. Thus, we recommend that the explanations of certain regulatory elements should be redefined and fixed especially for synthetic biology for easy communication, sharing and searching of information.

Common misuses of the terminology can guide us to figure out how to construct a standard nomenclature for synthetic biology. We claim that a standard nomenclature is urgently needed for synthetic biology for the following reasons. First of all, synthetic biology is an emerging research discipline and an industrial application area which is highly promising. Secondly, redefinition of the terminology to build a standard nomenclature is needed as some of the terms are prone to be used instead of another causing problems related to misuse for the global communication about synthetic biology. Lastly, the nomenclature has major importance for the construction of a persistent and trustworthy database for synthetic biology which serves for the information exhibition and exchange globally. For instance, there are obvious misunderstandings about the words which are predominantly used for regulation process. We have noticed that, the terms “inhibitor” and “repressor” are being used as equivocally in the part information pages. Like the lactose inhibitor protein, a widely used DNA-binding transcriptional repressor, that have been labeled both as “inhibitor” and “repressor” at iGEM’s Parts Registry. Similar problems resulting from ambiguous use of terminology also observed with regulatory elements. To sum up, we investigated all input elements for promoters and classify these elements in terms of their function, affect and required input element for them. So, we suggest that terminology used for regulation of transcription should be defined clearly on iGEM’s website and correct use of terminology should be enforced.

The second group of parameters was collected under the title “Output”, which refers to products of functional genes. In contradiction, the term “reporter” has also been described within the same list. Reporters are also genes whose products, can be used for screening as an output. According to our group, the usage of the term “reporter” for genes is unnecessary and cause extra complexity for information distribution and gives rise to discrepancies. Instead of using the term “reporter”, predefined “gene” description should be used for genes, which can function as reporters. The special information which is related with the characteristic of that gene should also be presented on part info web page.

Furthermore, the same terminology “reporter” was used for both atomic parts and composite bio-bricks. Also the overall image descriptions for these were defined as “reporters”. We want to point out that using same nomenclature for both atomic genes and for whole functional constructs contributes to the complexity and makes specific explorations difficult through the Parts Registry. So, assigning “reporter” for both atomic parts and for whole constructs is not a good practice. Instead, we are suggesting the usage of other available terminology for the parts listed as reporters, which most of the constructs, now known as reporters, can be grouped into, such as “protein generators”, “composite parts” or “inverters”.

Devices are whole constructs which are functional and have specific and distinct functions. But, as we have observed, unfortunately, the term “device” is also being used for parts which are not functional and do not have specific functional at all. Moreover, within the classification of devices, we argue that some terms are also being used unnecessarily and ambiguously. Devices are classified into five types which are protein generators, reporters, inverters, receivers and senders, measurement devices. For example iGEM defines protein generators as:

Protein generator = promoter + rbs +gene + terminator

Though we accept the definition for protein generators, we observed that there exist numerous parts which are defined as protein generators but actually most of them do not fit to the definition provided above. Although some parts are not functional and do not generate proteins at all, they are classified as protein generators, which makes searching for the parts difficult in the registry. Furthermore, there are also numerous parts which are defined as “composite parts” but actually they fit to the same definition with protein generators. In order to overcome the problem of misuse of device type we have extracted related image ID information for the composite parts. Image ID information helped us to correctly categorize composite parts depending on its individual atomic parts and identify the ones with more than one function, such as being both inhibitor and activator. In other words, we used image and part IDs in order to merge an input for its outputs.

Subtitle working conditions, includes all the detailed information about the experimental properties of parts, and the details about the working process of individual parts and complete devices. Additionally, we marked the subtitle “Working Condition” in our standardization template as potentially the most important title that helps synthetic biologist to better understand the parts functions at iGEM’s part registry database. The main problem we have encounter with the subtitle “working condition” is within most of the parts the details about working process is not enough and not provided regularly.


Examples of Misuse of Terminology:

For Composite Parts:

PartID: BBa_S04055

PartName: Synthetic lacYZ operon

This part is functional and responsible for the production of LacY and LacZ proteins. This part partially fits the definition for “composite part” but actually should be a protein generator as it fits fully to the definition of “protein generators”.

For Protein Generators:

PartID: BBa_J45299

PartName: PchA & PchB enzyme generator

The part which is illustrated above actually fits the definition for “composite part” but in part registry it is classified as protein generator. This part can be functional but it needs a promoter. Even though this part is not functional and is not capable of producing protein, part registry assigns this product as protein generator. We suggest that all parts in the registry, which are composed of more than one atomic part and which are not functional on their own but can be functional, should be classified as “composite parts”.

For Reporters:

PartID: BBa_J04451

PartName: RFP Coding Device with an LVA tag

This functional part is classified as “Reporter” in the parts registry database. It is very clear that this part fits the same description as Protein Generator in Biobrick part registry standards. Although, this part has specific and known functional role, characterizing this part as a reporter is unnecessary and contributes to the level of complexity of information provided. Instead, we suggest that this part should be classified as “protein generator” and related detailed information about the specific function of this part, should be provided in the part information page.

In conclusion, as mentioned above we tried to reorganize and normalize the information about parts which is provided in part registry for 2010 in order to develop our algorithm for the BioGuide application. During this process, we encountered some inconsistencies and misuses of the terminology being used and also inadequacies about the information provided about parts. First of all, we claim that a standard nomenclature should be constituted for future use in the field of synthetic biology. Based on the information gathered according to new nomenclature a professional database should be constructed to address the needs of synthetic biology. This will enable easy information exchange and exhibition globally. Secondly, although there are enough information about parts exists on parts registry database, the information which is provided for parts need to be ordered urgently. Furthermore, there should be new experimental standards which must be introduced to groups in the part submission process for the subtitle “working condition”. These experimental standards will be important because the experimental details about parts are not satisfying the needs of wet-lab biologists for the design and the construction of new Biobricks.

Contact

Algorithm

In this section, the step by step functioning of our application, along with the encapsulation of the algorithmic concepts of ‘standardization’ of functional iGEM devices are depicted in pictorial forms called flowcharts. Rectangular boxes represent the encapsulation of implementations of the computer programs to perform the particular tasks stated in that box on the flowcharts. These boxes are sometimes called subprograms, objects or packages in Object Oriented software Engineering context. The diamonds represent decision branching and they are found between two rectangular boxes. The arrows show the direction in which subprograms work and communicate. The subprogram at the head of the arrow starts executing after the termination of the subprogram at the tail of the arrow. Following flowcharts are the high level representations of our algorithms developed for the BioGuide software.


1

Diagram 1. Flowchart of collection, formatting and storage of devices data algorithm

Information about the iGEM parts had to be collected in a standardized format for our application to function properly. Following data collection custom subprograms is needed to parse and forward the data the application’s database. In order to achieve this we have designed and implemented the algorithm shown in diagram 1. In this algorithm, the first stage was to find the list of part IDs of devices which were supplied by iGEM in Spring 2010 distribution. This information has been collected from two sources 1) plate files in excel format which was available online 2) device data provided in xml format, both provided by iGEM. The last step in the algorithm was to send the collected partID data to the application’s database.


2.

Diagram 2. Flowchart for BioGuide execution before and during user interaction

Diagram 2 presents the main algorithm, which shows how BioGuide application works. In BioGuide the major components are device and Biobrick graphs. While the device graph represents input-output (promoter-regulator) compatibility combination of iGEM devices, the Biobrick graph represents combinations of atomic parts assembled in a device or system. The flowchart shows how these graphs are created and embedded into the program, which displays both of the graphs to the user when launched. Application presents few interactive options to the user when started, which were shown on the flowchart under the horizontal, bolded line. As shown on the diagram 2, there are four interactive tasks BioGuide can do, where the device and Biobricks graphs are utilized. Upon clicking a node on a devices or Biobricks graph, that node changes in size and color and the various functions shown on the flowchart can be performed then after.

Modeling

Graphical Modeling for Bio-Guide

Introduction

Graphical Modeling Theory has been applied to construct four different graphs where relations of atomic parts, devices and systems and the functional combinations that can build new constructs are presented for the iGEMs parts registry database. Three graphs are composed of iGEM devices and one graph is based on Biobricks. Each graph comprises a set of vertices or nodes and a set of edges. In the set of nodes each node represents a device, while in the set of edges each edge represents the input-output combination of the nodes. These graphs are directed graphs as the edges are created according to input-output combination. All compatibilities between a regulator and a promoter of an edge is created, where the source of this edge is the device with the corresponding regulator and target of the edge is the device with the promoter in concern.

Fig. 1: A node representing a device

Fig. 2: Arrow representing an edge between two nodes

The atomic structures used in our graphical model have been represented in Figures 1 and 2. A node is represented with a solid circle where the label, the part/device ID according to iGEM standards, of the device is marked on the foreground. The blue arrows between nodes connect the related devices, representing the input-output connectivity. End style of the arrow helps us to determine the direction of the node, like in Figure 2 where the node labeled BBa_S03520 is the source and BBa_JO9250 is the target.


Directivity

All the four constructed graphs build for BioGuide are directed graphs. So that, for every edge there must be a single source and a target. There is no single edge which is bidirectional. In mathematical form this can be represented as:

If an edge e has node v as source and node w as target then the edge can be expressed as

For a directed graph the combination (v, w) is totally different from (w, v). Therefore,

The direction of the edges has been represented with the arrows, as explained in Figure 2.


Connectivity

The nodes forming their own sub-graphs disconnected from the rest of the nodes have been recognized, which showed us the presence of incompatibility between few regulators and promoters of the devices. We have observed this disconnection in all four of our graphs. The basis of the disconnection has been shown in Figure 3, where the two sub-graphs without any edge that connects them to the main graph has been presented on the right hand side of the diagram. These features classify our graphs as disconnected graphs [1].

Fig. 3: A zoomed in screenshot showing two sub-graphs within the disconnected graph.


"Semi-Simplicity"

A simple graph is a graph in which no more than one edge contains the same set of nodes. So, in a simple graph it is not possible to find more than one edge with the same source and the same target. Additionally, an edge with the same source and target, forming a loop is not allowed. But, in synthetic biology it is possible to construct a device consisting of devices or bio bricks of the same species or type. Accordingly, our graphs are simple graphs with an exception of possible self-containing loops, where the edge starts from and ends on the same node. Our graphs have an exception of having loops and due to this permitted flexibility our graphs are "semi-simple".

For general information about graphs refer to:

[1] http://en.wikipedia.org/wiki/Graph_(mathematics)

Results