Team:SDU-Denmark/protocols

From 2010.igem.org

(Difference between revisions)
(Colony PCR)
m (Colony PCR)
Line 204: Line 204:
=== CP1.2 ===
=== CP1.2 ===
 +
<br>
 +
Updated Taq protocol for length determination. Due to Taq's lack of proofreading, only use this protocol for length determination.
 +
<br><br>
 +
''Protocol:''
 +
<br>
 +
1. A single colony is transfered to each eppendorf tube with a pipette tip. (The same tip is used to plate out on a LA+antibiotic plate afterwards) <br>
 +
2. Add 30 ul H2O to each tube.<br>
 +
3. Microwave with open lid at full power for 2 minutes.<br>
 +
4. Prepare Pre-Mix (number of colonies+1) Distribute 19ul to each tube.<br>
 +
5. shortly spin down PCR tubes
 +
6. Load and set PCR machine<br>
 +
7. Add TAQ polymerase at last moment. Make sure to get it under the surface of the solution.<br>
 +
8. Run PCR reaction.<br><br>
 +
''Pre-mix:''
 +
<br>
 +
5ul 10x TAQ buffer<br>
 +
2ul MgCl2 (Increase in 0.25ul incriments if the DNA you want to extract is longer than 3kb.)<br>
 +
2ul 10pmol/ul forward primer<br>
 +
2ul 10pmol/ul reverse primer<br>
 +
1ul 10mM dNTP mix<br>
 +
7ul H2O<br><br>
 +
 +
1ul TAQ polymerase -> NB! Pre-Mix is made without TAQ polymerase!<br>
 +
 +
''PCR program''
 +
<br>
 +
<table style="text-align: left; width: 394px; height: 200px;" border="1"
 +
cellpadding="2" cellspacing="2">
 +
<tr>
 +
<td style="vertical-align: top;">1<br>
 +
</td>
 +
<td style="vertical-align: top;">Start<br>
 +
</td>
 +
<td style="vertical-align: top;">94°C<br>
 +
</td>
 +
<td style="vertical-align: top;">2min<br>
 +
</td>
 +
</tr>
 +
<tr>
 +
<td style="vertical-align: top;">2<br>
 +
</td>
 +
<td style="vertical-align: top;">Denaturing<br>
 +
</td>
 +
<td style="vertical-align: top;">94°C</td>
 +
<td style="vertical-align: top;">1min<br>
 +
</td>
 +
</tr>
 +
<tr>
 +
<td style="vertical-align: top;">3<br>
 +
</td>
 +
<td style="vertical-align: top;">Annealing<br>
 +
</td>
 +
<td style="vertical-align: top;">55°C<br>
 +
</td>
 +
<td style="vertical-align: top;">1min<br>
 +
</td>
 +
</tr>
 +
<tr>
 +
<td style="vertical-align: top;">4<br>
 +
</td>
 +
<td style="vertical-align: top;">Elongation<br>
 +
</td>
 +
<td style="vertical-align: top;">72°C<br>
 +
</td>
 +
<td style="vertical-align: top;">2min<br>
 +
</td>
 +
</tr>
 +
<tr>
 +
<td style="vertical-align: top;">5<br>
 +
</td>
 +
<td style="vertical-align: top;">GOTO 2<br>
 +
</td>
 +
<td style="vertical-align: top;"><br>
 +
</td>
 +
<td style="vertical-align: top;">rep. 29x<br>
 +
</td>
 +
</tr>
 +
<tr>
 +
<td style="vertical-align: top;">6<br>
 +
</td>
 +
<td style="vertical-align: top;">End<br>
 +
</td>
 +
<td style="vertical-align: top;">72°C<br>
 +
</td>
 +
<td style="vertical-align: top;">3min<br>
 +
</td>
 +
</tr>
 +
<tr>
 +
<td style="vertical-align: top;">7<br>
 +
</td>
 +
<td style="vertical-align: top;">Hold<br>
 +
</td>
 +
<td style="vertical-align: top;">4°C<br>
 +
</td>
 +
<td style="vertical-align: top;">-<br>
 +
</td>
 +
</tr>
 +
</table>
 +
<br>
 +
Elongation time is adjusted according to the length of the template. (1 min for every 1Kbp)<br>
 +
 +
=== CP1.3 ===
<br>
<br>
Updated Taq protocol for length determination. Due to Taq's lack of proofreading, only use this protocol for length determination.
Updated Taq protocol for length determination. Due to Taq's lack of proofreading, only use this protocol for length determination.

Revision as of 12:41, 22 July 2010