Team:Newcastle/2 August 2010

From 2010.igem.org

(Difference between revisions)
(Conclusion)
(Solution for the problem)
Line 49: Line 49:
==Solution for the problem==
==Solution for the problem==
-
# If P1 buffer of the Qiagen miniprep kit is contaminated, then use a different kit. We have Promega miniprep kit which will be used tomorrow.
+
# If the buffers of the Qiagen miniprep kit is contaminated, then we will be using the  Promega miniprep kit.
-
# If RNAse enzyme is inactive, then add extra RNAse into the P1 buffer. We would be adding 10 µl in the P1 buffer solution.
+
# If the RNAse enzyme was degraded, then we will be adding 10 µl of fresh RNAse into the P1 buffer.  
{{Team:Newcastle/footer}}
{{Team:Newcastle/footer}}

Revision as of 21:23, 25 October 2010

iGEM Homepage Newcastle University BacillaFilla Homepage Image Map

Contents

Plasmid Miniprep Experiment

Aims

The aim of this experiment is to extract plasmid DNA from pSB1C3 and pSB1AK3 from E. coli DH5α cells using the Qiagen miniprep kit. The extracted DNA is then analysed using the Nanodrop machine.

Materials and Protocol

Please refer to: Minipreps for Qiagen miniprep protocol, Nanodrop Spectrophotometer for nanodrop protocol and Restriction digests for restriction digestion protocol.

Result

pSB1C3

(No. 1)

pSB1C3

(No. 2)

pSB1C3

(No. 3)

pSB1C3

(No. 4)

lacI

(No. 1)

lacI

(No. 2)

Double terminator

(No. 1)

Double terminator

(No. 2)

44.0 µl/ml 19.9 µl/ml 25.0 µl/ml 30.8 µl/ml 10.0 µl/ml 44.2 µl/ml 9.2 µl/ml 39.7 µl/ml

Table 1: Nanodrop spectrophotometer results. Table represents the amount of plasmid present in µl/ml quantity.

Discussion

In our experiment, the concentration of our plasmid DNA range from 19 µg/ml to 44 µg/ml. This value is lower than the standard value of 150 µg/ml for plasmid DNA extraction. The 260/280 nm ratio for all the samples is in the range of 2.0 to 2.4. These indicated that our sample is contaminated with RNA and the purity of our samples are low.

Conclusion

We are able to obtain plasmid DNA, however the concentartion and the purity of the samples are low. This could be due to the following reasons:

  1. The buffers might have been contaminated with RNA.
  2. RNAse enzyme might have degraded over time.

Solution for the problem

  1. If the buffers of the Qiagen miniprep kit is contaminated, then we will be using the Promega miniprep kit.
  2. If the RNAse enzyme was degraded, then we will be adding 10 µl of fresh RNAse into the P1 buffer.