2- Cell Sensor Experiments
- Myoglobin Assay: Our data acquired from myoglobin assay is not clear because absorbance acquired from cell density have interefered with myoglogin assay data. - CFU(Colony Forming Unit): We couldn’t observe growth of bacteria starting from 4th hour of fermentation. - Fluorescence measurements: Fluorescence was detected due to auto-fluorescence of CooA proteins. Since our bacteria cultures have expression vector, CooA is highly expressed which in turn causes fluorescence. Flask experiments - Culturing: We didn’t have enough time to test our final vector. Instead, we have used BBa_K352017 to test the RFP production. We have used 300 mL flasks with 80 mL LB culture. We have applied 80 Ml Carbon monoxide to some. The results were successful. Cultures induced with carbon monoxide successfully expressed red fluorescent protein. Myoglobin assay optimization - We have planned to measure CO presence with myoglobin assay. We used myoglobin purchased from Sigma to detect levels of Carbon monoxide. In our experiments, we couldn’t measure exact CO in the environment owing to the fact that sensitivity level of the myoglobin bonded with CO was not sufficient to observe absorbance at 540 nm. Signal quantification with fluorescence spectroscopy - Signal Quantification of pCooF-RBS-GFP-TT: For this experiment, the bacteria containing the vector having the construct and expression vector pTriEx is incubated in E.coli BL21 strain at different conditions. The results are as the following; |
|