Team:HokkaidoU Japan/Notebook/September13

From 2010.igem.org

(Difference between revisions)
 
(11 intermediate revisions not shown)
Line 1: Line 1:
-
{{Template:HokkaidoU_Japan}}
+
{{Template:HokkaidoU_Japan}}<div class="linkbar"><div class="prev">[[Team:HokkaidoU_Japan/Notebook/September10|September 10]]</div>[[Team:HokkaidoU_Japan/Notebook|Notebook]]<div class="next">[[Team:HokkaidoU_Japan/Notebook/September14|September 14]]</div></div>
-
=araCプロモーターのゲル抽精製=
+
 
-
[[Image:HokkaidoU Japan 20100913a.jpg‎|200px|right|thumb|]]
+
=araC promoter purification=
-
上のバンドはマーカーと比較するとやや小さいが,量が多すぎて流れたものと考え,これをゲル抽
+
 
-
* TSUDAの一番上は1250 bp
+
[[Image:HokkaidoU Japan 20100913a.jpg‎|200px|right|thumb|Electrophoresed for gel extraction]]
-
* 目的のバンドは1259 bp
+
 
 +
Compared to marker band was a little lower than it should. Thinking that this was due to too big an amount, gel extracted anyway.
 +
* Used [https://2010.igem.org/Image:HokkaidoU_Pictures_DNA_Marker.png TSUDA] marker
 +
* Part length is 1259 bp
<div style="clear:both;"></div>
<div style="clear:both;"></div>
-
=ゲル抽したものを電気泳動=
+
 
-
[[Image:HokkaidoU Japan 20100913b.jpg‎|200px|right|thumb|]]
+
=Electrophoresed after [[Team:HokkaidoU_Japan/Protocols|gel extraction]]=
-
* TSUDA I 2 uL, ゲル抽したものを0.5 uL泳動
+
 
-
→54 ng/uLと推定
+
[[Image:HokkaidoU Japan 20100913b.jpg‎|200px|right|thumb|Electrophoresis after purification]]
-
* 今度の位置はちゃんとしている
+
 
-
* ゲル抽時に別のバンドもとれてしまったみたい
+
* Electrophoresed [https://2010.igem.org/Image:HokkaidoU_Pictures_DNA_Marker.png TSUDA I] 2 uL and 0.5 uL of purified solution
 +
→Estimated concentration to be 54 ng/uL
 +
* This time band location is good
 +
* Accidentally excised a part of other band resulting small contamination
<div style="clear:both;"></div>
<div style="clear:both;"></div>
-
=GFP(1-12O)ゲル抽精製済の濃度測定=
+
=Gel purification of GFP([[Team:HokkaidoU_Japan/Material_And_Methods#Materials_And_Methods|1-12O]]) and concentration check=
-
[[Image:HokkaidoU Japan 20100913c.jpg‎|200px|right|thumb|]]
+
 
-
* TSUDA I 2 uL, DNA 0.5 uL
+
[[Image:HokkaidoU Japan 20100913c.jpg‎|200px|right|thumb|Electrophoresis for concentration check]]
-
→120 ng/uLと推定
+
 
-
* 878 + 220 bpが947 bpのマーカーのちょい上に来ている.OK.
+
* [https://2010.igem.org/Image:HokkaidoU_Pictures_DNA_Marker.png TSUDA I] 2 uL, DNA 0.5 uL
 +
→Estimated concentration to be 120 ng/uL
 +
* Part length is 878 + 220 bp = 947 bp
 +
* That slightly above mark so OK.

Latest revision as of 08:15, 27 October 2010

araC promoter purification

Electrophoresed for gel extraction

Compared to marker band was a little lower than it should. Thinking that this was due to too big an amount, gel extracted anyway.

  • Used TSUDA marker
  • Part length is 1259 bp

Electrophoresed after gel extraction

Electrophoresis after purification
  • Electrophoresed TSUDA I 2 uL and 0.5 uL of purified solution

→Estimated concentration to be 54 ng/uL

  • This time band location is good
  • Accidentally excised a part of other band resulting small contamination

Gel purification of GFP(1-12O) and concentration check

Electrophoresis for concentration check

→Estimated concentration to be 120 ng/uL

  • Part length is 878 + 220 bp = 947 bp
  • That slightly above mark so OK.