(One intermediate revision not shown) |
Line 1: |
Line 1: |
- | '''Wear gloves at all times!'''
| |
| | | |
- | Requirements:
| |
- | *30% acrylamide(Biorad) '''NEUROTOXIN!'''
| |
- | *4X separation gel buffer: 1.5M Tris.HCl, 0.4% SDS pH6.8
| |
- | *4X stacking gel buffer: 0.5M Tris.HCl, 1.92M glycine, 1% SDS water saturated isobutanol
| |
- | *TEMED( in yellow cabinet )
| |
- | *10% APS (Ammonium persulfate) ; prepare 10 ml and keep cold in fridge
| |
- |
| |
- | '''Hoeffer Mighty gel system'''
| |
- | Casting of the gel:
| |
- | *Per gel take one small glass plate with 'ears', one big white ceramic plate, two grey spacers with perpendicular plastic bits (0.75 mm), and one white comb (0.75 mm)
| |
- | *Clean the plates etc with soap, rinse with demiwater and ethanol, and dry
| |
- | *Assemble the system in the gel casting holder. Mark the line of separation/stacking
| |
- | *Mix the separation gel in 10 ml plastic tube:
| |
- | '''for 2 gels'''
| |
- | '''Seperation gel (0.75 mm)''' ''' 12.5%''' '''16%'''
| |
- | 30% acrylamide 4 ml 5.1 ml
| |
- | 4X separation buffer 2.4 ml 2.4 ml
| |
- | MQ 3.2 ml 2.1 ml
| |
- | 10% APS 28 μl 28 μl
| |
- | TEMED 28 μl 28 μl
| |
- | *Pipet the separation gel mix immediately in between the glass plates until the marked line is reached
| |
- | *Pipet water-saturated isobutanol on top of the polymerizing separation gel
| |
- | *Let the separation gel polymerize completely before preparing the stacking gel
| |
- | *When the gel is polymerized, discard the isobutanol and wash the gel with water
| |
- | *Mix the stacking gel in a 10 ml tube:
| |
- | '''for 2 gels'''
| |
- | mQ 1.92 ml
| |
- | 4X stacking buffer 0.83 ml
| |
- | 30% acrylamide 560 μl
| |
- | 10% APS 14 μl
| |
- | TEMED 7 μl
| |
- | *Pipet the stacking gel mix immediately on top of the separation gel and place the comb without air bubbles. Mark the teeth of the comb with a marker
| |
- | *Let the gel polymerize (5-30 min); check also the remaining gelmix in the tube
| |
- | *Disassemble the gel casting holder and take out the gel/plates
| |
- | *Use the gel immediately or seal the gel in plastic seal bags and store at 4 °C
| |
- |
| |
- | '''Assembly of the Tris-Glycine gel in the electrophoresis unit'''
| |